EUVIMEDEUVIMED entdecken
Crossref

A multicentre observational study evaluating image-guided radiotherapy for more accurate partial-breast intensity-modulated radiotherapy: comparison with standard imaging technique

Emma J Harris, Mukesh Mukesh, Rajesh Jena, Angela Baker, Harry Bartelink, Corrinne Brooks, June Dean, Ellen M Donovan, Sandra Collette, Sally Eagle, John D Fenwick, Peter H Graham und 13 weitere

Efficacy and Mechanism Evaluation · 2014

DOI: 10.3310/eme01030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Efficacy and Mechanism Evaluation, 2014. Verfasst von Emma J Harris und 24 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 120 Literaturangaben. Gefördert von: National Institute for Health Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Whole-breast radiotherapy (WBRT) is the standard treatment for breast cancer following breast-conserving surgery. Evidence shows that tumour recurrences occur near the original cancer: the tumour bed. New treatment developments include increasing dose to the tumour bed during WBRT (synchronous integrated boost) and irradiating only the region around the tumour bed, for patients at high and low risk of tumour recurrence, respectively. Currently, standard imaging uses bony anatomy to ensure accurate delivery of WBRT. It is debatable whether or not more targeted treatments such as synchronous integrated boost and partial-breast radiotherapy require image-guided radiotherapy (IGRT) focusing on implanted tumour bed clips (clip-based IGRT).

Objectives

Primary – to compare accuracy of patient set-up using standard imaging compared with clip-based IGRT. Secondary – comparison of imaging techniques using (1) tumour bed radiotherapy safety margins, (2) volume of breast tissue irradiated around tumour bed, (3) estimated breast toxicity following development of a normal tissue control probability model and (4) time taken.

Design

Multicentre observational study embedded within a national randomised trial: IMPORT-HIGH (Intensity Modulated and Partial Organ Radiotherapy – HIGHer-risk patient group) testing synchronous integrated boost and using clip-based IGRT.

Setting

Five radiotherapy departments, participating in IMPORT-HIGH.

Participants

Two-hundred and eighteen patients receiving breast radiotherapy within IMPORT-HIGH.

Interventions

There was no direct intervention in patients’ treatment. Experimental and control intervention were clip-based IGRT and standard imaging, respectively. IMPORT-HIGH patients received clip-based IGRT as routine; standard imaging data were obtained from clip-based IGRT images. Main outcome measures Difference in (1) set-up errors, (2) safety margins, (3) volume of breast tissue irradiated, (4) breast toxicity and (5) time, between clip-based IGRT and standard imaging.

Results

The primary outcome of overall mean difference in clip-based IGRT and standard imaging using daily set-up errors was 2–2.6 mm ( p < 0.001). Heterogeneity testing between centres found a statistically significant difference in set-up errors at one centre. For four centres (179 patients), clip-based IGRT gave a mean decrease in the systematic set-up error of between 1 mm and 2 mm compared with standard imaging. Secondary outcomes were as follows: clip-based IGRT and standard imaging safety margins were less than 5 mm and 8 mm, respectively. Using clip-based IGRT, the median volume of tissue receiving 95% of prescribed boost dose decreased by 29 cm 3 (range 11–193 cm 3 ) compared with standard imaging. Difference in median time required to perform clip-based IGRT compared with standard imaging was X-ray imaging technique dependent (range 8–76 seconds). It was not possible to estimate differences in breast toxicity, the normal tissue control probability model indicated that for breast fibrosis maximum radiotherapy dose is more important than volume of tissue irradiated. Conclusions and implications for clinical practice Margins of less than 8 mm cannot be used safely without clip-based IGRT for patients receiving concomitant tumour bed boost, as there is a risk of geographical miss of the tumour bed being treated. In principle, smaller but accurately placed margins may influence local control and toxicity rates, but this needs to be evaluated from mature clinical trial data in the future. Funding The National Institute for Health Research Efficacy and Mechanism Evaluation programme.

Förderung

  • National Institute for Health Research

Zitieren

APA

Harris, E. J., Mukesh, M., Jena, R., Baker, A., Bartelink, H., Brooks, C., Dean, J., Donovan, E. M., Collette, S., Eagle, S., Fenwick, J. D., Graham, P. H., Haviland, J. S., Kirby, A. M., Mayles, H., Mitchell, R. A., Perry, R., Poortmans, P., Poynter, A., …, & Evans, P. M. (2014). A multicentre observational study evaluating image-guided radiotherapy for more accurate partial-breast intensity-modulated radiotherapy: comparison with standard imaging technique. Efficacy and Mechanism Evaluation. https://doi.org/10.3310/eme01030

Vancouver

Harris EJ, Mukesh M, Jena R, Baker A, Bartelink H, Brooks C, et al. A multicentre observational study evaluating image-guided radiotherapy for more accurate partial-breast intensity-modulated radiotherapy: comparison with standard imaging technique. Efficacy and Mechanism Evaluation. 2014. doi:10.3310/eme01030

BibTeX
@article{Harris2014,
  author = {Harris, Emma J and Mukesh, Mukesh and Jena, Rajesh and Baker, Angela and Bartelink, Harry and Brooks, Corrinne and Dean, June and Donovan, Ellen M and Collette, Sandra and Eagle, Sally and Fenwick, John D and Graham, Peter H and Haviland, Jo S and Kirby, Anna M and Mayles, Helen and Mitchell, Robert A and Perry, Rosalind and Poortmans, Philip and Poynter, Andrew and Shentall, Glyn and Titley, Jenny and Thompson, Alistair and Yarnold, John R and Coles, Charlotte E and Evans, Philip M},
  title = {A multicentre observational study evaluating image-guided radiotherapy for more accurate partial-breast intensity-modulated radiotherapy: comparison with standard imaging technique},
  journal = {Efficacy and Mechanism Evaluation},
  year = {2014},
  doi = {10.3310/eme01030}
}
Kostenlos starten →