Kurz gefasst

Fachartikel in der Zeitschrift Energy Technologies & Resource Saving, online erschienen am 12.07.2026. Verfasst von M.V. Chernyavskyy und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the context of wartime conditions and severe damage to Ukraine’s energy infrastructure, the load-regulation range of each surviving pulverized-coal-fired power unit has become critically important. This paper analyses the factors limiting the minimum permissible load of Ukrainian boilers compared with modern international boiler designs and demonstrates that, for 300 MW supercritical once-through anthracite-fired boilers converted to bituminous coal combustion, the main possibility for expanding the load regulation range lies in eliminating the risk of inter-pipe pulsations in furnace waterwalls during low-load and sliding-pressure operation. An analytical approach has been developed to address the principal challenges associated with evaluating the hydraulic reliability of once-through supercritical boilers. Based on thermohydraulic calculations of the TPP-210A supercritical once-through boiler converted from anthracite to bituminous coal firing, it has been shown that the increase in the critical mass velocity above the actual mass velocity, and consequently the occurrence of inter-pipe pulsations at low loads, is associated with the slower decrease in the specific heat flux absorbed by the lower furnace waterwalls compared with the reduction in the boiler thermal load. A new technical solution is proposed for eliminating inter-pipe pulsations by installing diaphragms only at the inlet of the most thermally stressed central waterwall panels of the lower radiant furnace section. An effective method has been developed for eliminating the risk of inter-pipe pulsations and thermal damage to the waterwall pipes of a once-through pulverized bituminous coal-fired supercritical boiler, allowing the minimum permissible load to be reduced from 70 % to 30–40 % of nominal capacity. This significantly expands the load-following capability of thermal power plant units within the Ukrainian power system. Bibl. 30, Tab. 2, Fig. 8.

Zitieren

APA

Chernyavskyy, M., Shchudlo, T., Beztsennyi, I., & Fateiev, A. (2026). THE RESULTS OF NUMERICAL INVESTIGATION OF HERMOHYDRAULIC PROCESSES IN TPP-210A BOILER WATERWALLS AND TECHNICAL SOLUTIONS FOR EXPANDING THE LOAD REGULATION RANGE. Energy Technologies & Resource Saving, 87(2), 44-59. https://doi.org/10.33070/etars.2.2026.03

Vancouver

Chernyavskyy M, Shchudlo T, Beztsennyi I, Fateiev A. THE RESULTS OF NUMERICAL INVESTIGATION OF HERMOHYDRAULIC PROCESSES IN TPP-210A BOILER WATERWALLS AND TECHNICAL SOLUTIONS FOR EXPANDING THE LOAD REGULATION RANGE. Energy Technologies & Resource Saving. 2026;87(2):44-59. doi:10.33070/etars.2.2026.03

BibTeX
@article{Chernyavskyy2026,
  author = {Chernyavskyy, M.V. and Shchudlo, T.S. and Beztsennyi, I.V. and Fateiev, A.I.},
  title = {THE RESULTS OF NUMERICAL INVESTIGATION OF HERMOHYDRAULIC PROCESSES IN TPP-210A BOILER WATERWALLS AND TECHNICAL SOLUTIONS FOR EXPANDING THE LOAD REGULATION RANGE},
  journal = {Energy Technologies & Resource Saving},
  year = {2026},
  volume = {87},
  number = {2},
  pages = {44--59},
  doi = {10.33070/etars.2.2026.03}
}