Differences in maxillary sinus volume measurements between linear dimensional and semi-automatic segmentation methods on CBCT
Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI) · 2026
DOI: 10.32793/jrdi.v10i2.1574 ↗Kurz gefasst
Fachartikel in der Zeitschrift Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI), 2026. Verfasst von Diana Ann und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objectives
This study aimed to analyze the differences in maxillary sinus volume measurements between the linear dimension method and the semi-automatic segmentation method using CBCT images. Maxillary sinus volume is an important anatomical parameter that reflects variations in sinus morphology and pneumatization and may support clinical assessment and treatment planning. Materials and Methods: This comparative analytical study used secondary CBCT radiographic data of patients aged 20–40 years from the Radiology Unit of RSGM FKG USAKTI. A total of 50 samples, or 100 maxillary sinuses, were analyzed using two measurement methods, namely the linear dimension method and the semi-automatic segmentation method.
Results
The mean maxillary sinus volume measured using the linear dimension method was 24,501.85 mm³ on the right side and 25,004.67 mm³ on the left side. In contrast, measurements obtained using the semi-automated segmentation method yielded mean volumes of 17,720.65 mm³ for the right maxillary sinus and 18,455.25 mm³ for the left maxillary sinus. The paired t-test demonstrated mean differences of 8,325.4 mm³ on the right side and 10,701 mm³ on the left side between the two measurement methods. These results indicate a difference between maxillary sinus volume measurements obtained using the linear dimension method and the semi-automatic segmentation method.
Conclusion
Volume measurements obtained using the semi-automatic segmentation method are closer to the average normal maxillary sinus volume
Zitieren
APA
Ann, D., Lubis, M. N. P., Arifin, S. P. A., Farizka, I., Palupi, A. P. S., & Ariyani, A. P. (2026). Differences in maxillary sinus volume measurements between linear dimensional and semi-automatic segmentation methods on CBCT. Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI). https://doi.org/10.32793/jrdi.v10i2.1574
Vancouver
Ann D, Lubis MNP, Arifin SPA, Farizka I, Palupi APS, Ariyani AP. Differences in maxillary sinus volume measurements between linear dimensional and semi-automatic segmentation methods on CBCT. Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI). 2026. doi:10.32793/jrdi.v10i2.1574
BibTeX
@article{Ann2026,
author = {Ann, Diana and Lubis, M. Novo Perwira and Arifin, Sariyani Pancasari Audry and Farizka, Intan and Palupi, Anggraeny Putri Sekar and Ariyani, Annisaa Putri},
title = {Differences in maxillary sinus volume measurements between linear dimensional and semi-automatic segmentation methods on CBCT},
journal = {Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI)},
year = {2026},
doi = {10.32793/jrdi.v10i2.1574}
}
EUVIMED