EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Protected Specimen Brush (PSB) or Bronchoalveolar Lavage (BAL) for Diagnosing Ventilator-Associated Pneumonia

Haval Othman Ali, Kawa Wsu Hassan

University of Thi-Qar Journal Of Medicine · 2024

DOI: 10.32792/jmed.v28i2.547 ↗

Kurz gefasst

Fachartikel in der Zeitschrift University of Thi-Qar Journal Of Medicine, 2024. Verfasst von Haval Othman Ali und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ventilator-associated pneumonia (VAP) is a common and serious infection in intubated patients, leading to increased mortality, longer ICU stays, and higher healthcare costs. Accurate diagnosis is essential for effective treatment and to prevent antibiotic misuse.

Purpose

This study investigates whether bronchoalveolar lavage (BAL) and protected specimen brush (PSB) yield similar culture results in ICU patients with suspected or confirmed VAP.

Methods

A retrospective study was conducted on ICU patients with VAP at Shar Hospital, Sulaymaniyah, Iraq, from 2020 to 2023. Patients on ventilators for ≥48 hours with new lung infiltrates who underwent both BAL and PSB were included. Spearman's correlation was used to compare culture results.

Results

Out of 56 VAP patients, 20 met inclusion criteria. Bacteria were detected in 48% of BAL and 43% of PSB samples. A significant correlation was found between BAL and PSB results (correlation coefficient 0.846, p < 0.01), with 96% agreement in detected agents.

Conclusion

PSB and BAL provide comparable results for diagnosing VAP, but PSB might be preferred due to its specificity and lower risk of procedural complications. Correct BAL technique, involving adequate saline flushing, is essential for accurate results. Further studies should standardize BAL procedures to optimize diagnostic accuracy

Zitieren

APA

Ali, H. O., & Hassan, K. W. (2024). Protected Specimen Brush (PSB) or Bronchoalveolar Lavage (BAL) for Diagnosing Ventilator-Associated Pneumonia. University of Thi-Qar Journal Of Medicine. https://doi.org/10.32792/jmed.v28i2.547

Vancouver

Ali HO, Hassan KW. Protected Specimen Brush (PSB) or Bronchoalveolar Lavage (BAL) for Diagnosing Ventilator-Associated Pneumonia. University of Thi-Qar Journal Of Medicine. 2024. doi:10.32792/jmed.v28i2.547

BibTeX
@article{Ali2024,
  author = {Ali, Haval Othman and Hassan, Kawa Wsu},
  title = {Protected Specimen Brush (PSB) or Bronchoalveolar Lavage (BAL) for Diagnosing Ventilator-Associated Pneumonia},
  journal = {University of Thi-Qar Journal Of Medicine},
  year = {2024},
  doi = {10.32792/jmed.v28i2.547}
}
Kostenlos starten →