EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Five-year outcomes of posterior chamber phakic implantable collamer lens implantation in high myopia, keratoconus, and post-keratoplasty eyes

Iveta Nemcova, Jiri Pasta, Katerina Hladikova, Martin Komarc, Darina Pospisilova, Jan Havlik, Jan Tesar, Vladimir Kratky, Martin Sin

Journal of Applied Biomedicine · 18.06.2026 · 24 (2) · 72-80

DOI: 10.32725/jab.2026.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Biomedicine, erschienen am 18.06.2026. Verfasst von Iveta Nemcova und 8 weiteren Autor:innen. Beteiligte Einrichtung: Military University Hospital Prague, Department of Ophthalmology, Prague, Czech Republic. Hauptthemen laut MEDLINE: Keratoconus, Phakic Intraocular Lenses, Myopia, Lens Implantation, Intraocular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To report on a 5-year follow-up of Implantable Collamer Lenses (ICL) implantation and compare it to previously published iris-fixated phakic intraocular lenses (IF pIOLs). METHODS: We describe the refractive results and adverse events of 30 eyes in 18 patients with high myopia, keratoconus, or status post-keratoplasty (PKP), at one, two and five years after surgery. RESULTS: Efficacy and safety index were 0.94 and 1.04, respectively, at 5 years after surgery. Intraocular pressure (IOP) was significantly higher postoperatively (p = 0.005). The endothelial cell loss (EC loss) caused by the ICL implantation was found to be 3.82%, 5.03%, and 11.41%, at one-, two-, and five-years post-surgery. During a 5-year follow-up, 92% of eyes lost a higher percentage of endothelial cells (EC) than the expected physiological loss. Among eyes with >25% EC loss, all affected eyes at 2 years, and 80% at 5 years, had either keratoconus or history of keratoplasty prior to ICL implantation. Postoperative EC loss positively correlated with preoperative keratometry and negatively with preoperative pachymetry. Significant inverse relationship was found between baseline and postoperative anterior chamber angle (ACA) and EC loss. Postoperative vault (388 ± 159 μm) showed a negative correlation with endothelial cell density (ECD) in 5-year follow-up. There was no cataract formation at 5 years postoperatively. CONCLUSION: Compared to the IF pIOLs, the V4c ICLs have similar frequency of postoperative cataract formation but appear to be safer for the endothelium. Therefore, they are likely more suitable for keratoconus and PKP patients. However, the risk of long term IOP elevation seems to be higher.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KeratoconusPhakic Intraocular LensesMyopiaLens Implantation, IntraocularHumansFemaleAdultMaleTreatment OutcomeIntraocular PressureFollow-Up StudiesYoung AdultMiddle Aged

Stichwörter der Autor:innen

Endothelial cell densityImplantable Collamer LensIntraocular pressureIris-fixated phakic intraocular lensKeratometryPachymetry

Autor:innen und Institutionen

  • Military University Hospital Prague, Department of Ophthalmology, Prague, Czech Republic.
  • Charles University, 1st Faculty of Medicine, Prague, Czech Republic.
  • Charles University, Faculty of Physical Education and Sport, Department of Methodology, Prague, Czech Republic.
  • Queen's University, Kingston Health Sciences Centre, Kingston, Canada.

Zitieren

APA

Nemcova, I., Pasta, J., Hladikova, K., Komarc, M., Pospisilova, D., Havlik, J., Tesar, J., Kratky, V., & Sin, M. (2026). Five-year outcomes of posterior chamber phakic implantable collamer lens implantation in high myopia, keratoconus, and post-keratoplasty eyes. Journal of Applied Biomedicine, 24(2), 72-80. https://doi.org/10.32725/jab.2026.004

Vancouver

Nemcova I, Pasta J, Hladikova K, Komarc M, Pospisilova D, Havlik J, et al. Five-year outcomes of posterior chamber phakic implantable collamer lens implantation in high myopia, keratoconus, and post-keratoplasty eyes. Journal of Applied Biomedicine. 2026;24(2):72-80. doi:10.32725/jab.2026.004

BibTeX
@article{Nemcova2026,
  author = {Nemcova, Iveta and Pasta, Jiri and Hladikova, Katerina and Komarc, Martin and Pospisilova, Darina and Havlik, Jan and Tesar, Jan and Kratky, Vladimir and Sin, Martin},
  title = {Five-year outcomes of posterior chamber phakic implantable collamer lens implantation in high myopia, keratoconus, and post-keratoplasty eyes},
  journal = {Journal of Applied Biomedicine},
  year = {2026},
  volume = {24},
  number = {2},
  pages = {72--80},
  doi = {10.32725/jab.2026.004}
}
Kostenlos starten →