EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Evaluation of 850°C Heat Treatment: Effects of Used-Oil Quenching, Brine Quenching, and Pack Carburizing on the Rockwell Hardness of ST37 Shredder Blades

Rahmat Fajrul, Reinaldi Teguh Setyawan, Zaid Ahmad, Gunawan Gunawan

Jurnal Mekanik Terapan · 30.04.2026 · 7 (1) · 30-39

DOI: 10.32722/jmt.v7i1.8320 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Mekanik Terapan, online erschienen am 30.04.2026. Verfasst von Rahmat Fajrul und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Waste shredder blades operate under abrasive contact and intermittent impacts from heterogeneous materials, making surface hardness a key property for maintaining cutting performance and reducing premature dulling. This study evaluates the effect of a 850°C heat-treatment route on the hardness of ST37 low-carbon steel used for shredder-blade applications. Plate specimens (100 mm × 100 mm × 10 mm) were prepared and tested under four conditions: untreated (as-received), pack carburizing using coconut-shell charcoal followed by furnace cooling, quenching in used oil, and quenching in saltwater (brine). Hardness was measured using the Rockwell C method (ASTM E18) with a diamond cone indenter (10 kgf minor load and 150 kgf major load). For each condition, ten hardness readings were collected and analyzed using one-way ANOVA (α = 0.05).The untreated specimens yielded an average hardness of 83.85 HRC. The pack-carburized and furnace-cooled condition resulted in a substantial decrease to 69.35 HRC, accompanied by higher variability, indicating a less favorable hardness response under the applied cooling route. In contrast, quenching after heating at 850°C increased hardness to 85.55 HRC for used-oil quenching and 88.35 HRC for brine quenching, with brine showing the highest mean value but also a wider scatter. ANOVA confirmed that the treatment route significantly influenced hardness (p < 0.05). Overall, the results indicate that, under the present parameters, quenching routes are more effective than the pack carburizing + furnace cooling route for improving blade hardness, while process consistency is important to control hardness dispersion, particularly for brine quenching.

Zitieren

APA

Fajrul, R., Setyawan, R. T., Ahmad, Z., & Gunawan, G. (2026). Evaluation of 850°C Heat Treatment: Effects of Used-Oil Quenching, Brine Quenching, and Pack Carburizing on the Rockwell Hardness of ST37 Shredder Blades. Jurnal Mekanik Terapan, 7(1), 30-39. https://doi.org/10.32722/jmt.v7i1.8320

Vancouver

Fajrul R, Setyawan RT, Ahmad Z, Gunawan G. Evaluation of 850°C Heat Treatment: Effects of Used-Oil Quenching, Brine Quenching, and Pack Carburizing on the Rockwell Hardness of ST37 Shredder Blades. Jurnal Mekanik Terapan. 2026;7(1):30-39. doi:10.32722/jmt.v7i1.8320

BibTeX
@article{Fajrul2026,
  author = {Fajrul, Rahmat and Setyawan, Reinaldi Teguh and Ahmad, Zaid and Gunawan, Gunawan},
  title = {Evaluation of 850°C Heat Treatment: Effects of Used-Oil Quenching, Brine Quenching, and Pack Carburizing on the Rockwell Hardness of ST37 Shredder Blades},
  journal = {Jurnal Mekanik Terapan},
  year = {2026},
  volume = {7},
  number = {1},
  pages = {30--39},
  doi = {10.32722/jmt.v7i1.8320}
}
Kostenlos starten →