PERFORMANCE AND COLLAPSE PATTERNS OF EARTHQUAKE-RESISTANT BUILDINGS WITH FLOATING COLUMN

Divya Jhiehanira Widha Purnawirawan, Amalia, Jonathan Saputra

Applied Research on Civil Engineering and Environment (ARCEE) · 30.04.2026 · 7 (1) · 14-25

DOI: 10.32722/arcee.v7i1.7682 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Research on Civil Engineering and Environment (ARCEE), online erschienen am 30.04.2026. Verfasst von Divya Jhiehanira Widha Purnawirawan und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The need for space in buildings increases with population and aesthetic needs. The application of a floating column is an alternative solution, however, it increases flexibility and decreases strength due to stiffness discontinuity. This research analyzes the effect of floating columns on the performance and collapse pattern of medium-rise earthquake-resistant building structures using an 8-story deep building model. Structure using an 8-story interior building model. Model I building without floating columns, model II building with floating columns on the 6th floor, and model III with floating column on the 5th and 7th floors. Results show a decrease in base shearforce of 0.35% in model II and 0.46% in model III compared to model I. The largest displacement was recorded on the 8th floor, with an increase in model II of 0.03% (X-axis) and 0.04% (Y-axis), as well as in model III. (Y-axis), and in model III by 4% (X- axis) and 6.2% (Y-axis). The inter-storey deviation also increased but remained below the permitted limit of SNI 1726:2019. 1726:2019. Pushover analysis shows that all models have a drift ratio of 0.01-0.02 at the damage control performance level. Models I and II have a collapse beam side sway mechanism, while model III has a soft story mechanism, due to variations in floating column placement that increase the risk of collapse. Model II is considered to be the most optimal in terms of floating column placement based on displacement, inter-story deviation, base shear, performance level, and collapse pattern. collapse pattern.

Zitieren

APA

Purnawirawan, D. J. W., Amalia, & Saputra, J. (2026). PERFORMANCE AND COLLAPSE PATTERNS OF EARTHQUAKE-RESISTANT BUILDINGS WITH FLOATING COLUMN. Applied Research on Civil Engineering and Environment (ARCEE), 7(1), 14-25. https://doi.org/10.32722/arcee.v7i1.7682

Vancouver

Purnawirawan DJW, Amalia, Saputra J. PERFORMANCE AND COLLAPSE PATTERNS OF EARTHQUAKE-RESISTANT BUILDINGS WITH FLOATING COLUMN. Applied Research on Civil Engineering and Environment (ARCEE). 2026;7(1):14-25. doi:10.32722/arcee.v7i1.7682

BibTeX
@article{Purnawirawan2026,
  author = {Purnawirawan, Divya Jhiehanira Widha and Amalia and Saputra, Jonathan},
  title = {PERFORMANCE AND COLLAPSE PATTERNS OF EARTHQUAKE-RESISTANT BUILDINGS WITH FLOATING COLUMN},
  journal = {Applied Research on Civil Engineering and Environment (ARCEE)},
  year = {2026},
  volume = {7},
  number = {1},
  pages = {14--25},
  doi = {10.32722/arcee.v7i1.7682}
}
Kostenlos starten →