EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Performance Analysis of Earthquake-Resistant Building Structures with Conventional Columns and Flat Columns

Andika Dwi Pangestu, Amalia Amalia, Ega Edistria Edistria

Applied Research on Civil Engineering and Environment (ARCEE) · 30.09.2024 · 5 (02) · 57-71

DOI: 10.32722/arcee.v5i02.7054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Research on Civil Engineering and Environment (ARCEE), online erschienen am 30.09.2024. Verfasst von Andika Dwi Pangestu und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The structural integrity of a building depends on the ability of its column components to support the loads above them. The strength of a column is greatly influenced by its shape and dimensions. This study aims to analyze the performance of earthquake-resistant building structures with conventional columns and flat columns. This research was conducted by modeling two variations of an 8-story building structure using ETABS software, which are Model 1 with conventional columns and Model 2 with a combination of conventional columns and flat columns using L-shaped and T-shaped columns. The analysis of earthquake loads was performed by using the response spectrum analysis method, while the structural performance and the collapse mechanism of the building were performed by using the pushover analysis method. The results showed that Model 1 had smaller values of internal force, base shear, displacement, and inter-storey drift than Model 2. The results of the structural performance level in both models had the same level, which is Damage Control (DC). The structural collapse mechanism in Model 1 has qualified the requirement of strong column weak beam, while Model 2 has not met this requirement and falls into the column sway mechanism because the first collapse happened in columns. Based on the statistics analysis, there is no significant difference between Model 1 and Model 2, but in terms of maintaining the room area and aesthetic interior, Model 2 with flat columns has more value.

Zitieren

APA

Pangestu, A. D., Amalia, A., & Edistria, E. E. (2024). Performance Analysis of Earthquake-Resistant Building Structures with Conventional Columns and Flat Columns. Applied Research on Civil Engineering and Environment (ARCEE), 5(02), 57-71. https://doi.org/10.32722/arcee.v5i02.7054

Vancouver

Pangestu AD, Amalia A, Edistria EE. Performance Analysis of Earthquake-Resistant Building Structures with Conventional Columns and Flat Columns. Applied Research on Civil Engineering and Environment (ARCEE). 2024;5(02):57-71. doi:10.32722/arcee.v5i02.7054

BibTeX
@article{Pangestu2024,
  author = {Pangestu, Andika Dwi and Amalia, Amalia and Edistria, Ega Edistria},
  title = {Performance Analysis of Earthquake-Resistant Building Structures with Conventional Columns and Flat Columns},
  journal = {Applied Research on Civil Engineering and Environment (ARCEE)},
  year = {2024},
  volume = {5},
  number = {02},
  pages = {57--71},
  doi = {10.32722/arcee.v5i02.7054}
}
Kostenlos starten →