Gold Electrode Modified with Vanadium Dioxide and Graphene Oxide for Non-Enzymatic Electrochemical Detection of Glucose
International Journal of Scientific Research in Science and Technology · 20.04.2026 · 13 (2) · 876-887
DOI: 10.32628/ijsrst2613114 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Scientific Research in Science and Technology, online erschienen am 20.04.2026. Verfasst von E. T. S. Neves und 3 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This work presents the development of a non-enzymatic glucose sensor based on a gold electrode modified with a composite of vanadium dioxide (VO2) and graphene oxide (GO). The VO2 was synthesized via a facile hydrothermal method and combined with GO to form a thin film on the Au electrode surface. The electrochemical behavior of the Au/VO2-GO electrode was thoroughly investigated. The modified electrode exhibited a pH sensitivity of 58.0 ± 0.02 mV/pH, closely approximating the theoretical Nernstian response. The electrocatalytic activity towards glucose oxidation was assessed using cyclic voltammetry and square-wave voltammetry in synthetic urine. The anodic peak current increased linearly with glucose concentration in the range of 4.0 to 5.4 mmol.L⁻¹. The sensor demonstrated a detection limit of 0.65 mmol L⁻¹ and a quantification limit of 2.15 mmol.L⁻¹. The electrochemical process was identified as diffusion-controlled. Despite a relatively low electroactive surface area (roughness factor = 1.3 × 10-3), the Au/VO2-GO electrode showed promising sensitivity and stability for non-enzymatic glucose detection, suggesting potential for application in clinical analysis.
Zitieren
APA
Neves, E. T. S., Filho, R. G. C., Guerra, E. M., & Cestarolli, D. T. (2026). Gold Electrode Modified with Vanadium Dioxide and Graphene Oxide for Non-Enzymatic Electrochemical Detection of Glucose. International Journal of Scientific Research in Science and Technology, 13(2), 876-887. https://doi.org/10.32628/ijsrst2613114
Vancouver
Neves ETS, Filho RGC, Guerra EM, Cestarolli DT. Gold Electrode Modified with Vanadium Dioxide and Graphene Oxide for Non-Enzymatic Electrochemical Detection of Glucose. International Journal of Scientific Research in Science and Technology. 2026;13(2):876-887. doi:10.32628/ijsrst2613114
BibTeX
@article{Neves2026,
author = {Neves, E. T. S. and Filho, R. G. Cunha and Guerra, E. M. and Cestarolli, D. T.},
title = {Gold Electrode Modified with Vanadium Dioxide and Graphene Oxide for Non-Enzymatic Electrochemical Detection of Glucose},
journal = {International Journal of Scientific Research in Science and Technology},
year = {2026},
volume = {13},
number = {2},
pages = {876--887},
doi = {10.32628/ijsrst2613114}
}
EUVIMED