EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental Thermal–Hydraulic Evaluation of Continuous and Notched-Fin Liquid–Suction Heat Exchangers in an R407C Freezing System

Ayad Dawood Sulaiman

International Journal of Scientific Research in Science, Engineering and Technology · 15.11.2026 · 13 (6) · 77-90

DOI: 10.32628/ijsrset2613601 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Scientific Research in Science, Engineering and Technology, online erschienen am 15.11.2026. Verfasst von Ayad Dawood Sulaiman. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid–suction heat exchangers subcool the liquid line of a refrigeration cycle and protect the compressor, but in small freezing units their duty is usually limited by weak heat transfer on the suction-vapor side. This study adds a longitudinal fin on that side and examines whether notching the fin improves it further. In each of three exchangers, a copper fin 10 mm high and 1 mm thick was brazed under the liquid line and inserted through a slot into the suction line over a 600 mm contact length. The fin was continuous or carried 9 or 17 notches, each 5 mm wide and 5 mm deep. Each exchanger was installed in turn in an R407C freezing system serving a 15 m³ cold room and compared with the same cycle without an exchanger at evaporating temperatures from −25 to −10 °C. The effectiveness rose with the number of notches, reaching 0.14, 0.28 and 0.38 at −10 °C, although the notches removed up to 5.4% of the fin area. At −25 °C, the coefficient of performance increased from 2.59 to 2.80, 3.03 and 3.18, the refrigeration capacity of the 17-notch exchanger rose from 4.96 to 5.35 kW, and the compressor work fell by up to 12.4%. The metered daily energy use dropped by 5.7%, 7.3% and 10.4%. The cost was a higher suction-side pressure drop, which reached 7.6 kPa with 17 notches, so the notch density should be chosen against the suction pressure loss that the compressor can accept.

Zitieren

APA

Sulaiman, A. D. (2026). Experimental Thermal–Hydraulic Evaluation of Continuous and Notched-Fin Liquid–Suction Heat Exchangers in an R407C Freezing System. International Journal of Scientific Research in Science, Engineering and Technology, 13(6), 77-90. https://doi.org/10.32628/ijsrset2613601

Vancouver

Sulaiman AD. Experimental Thermal–Hydraulic Evaluation of Continuous and Notched-Fin Liquid–Suction Heat Exchangers in an R407C Freezing System. International Journal of Scientific Research in Science, Engineering and Technology. 2026;13(6):77-90. doi:10.32628/ijsrset2613601

BibTeX
@article{Sulaiman2026,
  author = {Sulaiman, Ayad Dawood},
  title = {Experimental Thermal–Hydraulic Evaluation of Continuous and Notched-Fin Liquid–Suction Heat Exchangers in an R407C Freezing System},
  journal = {International Journal of Scientific Research in Science, Engineering and Technology},
  year = {2026},
  volume = {13},
  number = {6},
  pages = {77--90},
  doi = {10.32628/ijsrset2613601}
}
Kostenlos starten →