A Highly Selective and Sensitive Potentiometric Sensor for Copper (II) Ions Using a Schiff Base-Derived Ionophore (E)-2 ((1H-pyrrol-2-yl) methylene amino) benzenethiol
International Journal of Scientific Research in Chemistry · 18.06.2026 · 11 (3) · 51-63
DOI: 10.32628/ijsrch261136 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Scientific Research in Chemistry, online erschienen am 18.06.2026. Verfasst von Narendra Kumar. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A copper (II)-selective electrode based on a PVC membrane was fabricated using the Schiff base (E)-2-((1H-pyrrol-2-yl) methylene amino) benzenethiol (I) as the ionophore, and its performance was systematically evaluated. The optimized membrane composition consisted of PVC, ionophore, and plasticizer in a 35:2:63 ratio. The sensor exhibited a Nernstian response toward Cu²⁺ ions, with a detection limit of 2.0 × 10⁻8 M and an effective linear range from 3.1 × 10⁻8 M to 1.0 × 10⁻¹ M. A rapid response time of about 8 seconds was observed upon immersion in the test solution. The electrode potential remained stable across a pH interval of 2.0 to 10 The electrode exhibited stable and reliable performance for nearly four months without any noticeable potential drift. In addition, it showed excellent selectivity toward Cu²⁺ ions in the presence of alkali, alkaline earth, transition, and other heavy metal ions. The sensor was effectively employed as an indicator electrode in the potentiometric titration of Cu²⁺ with EDTA and was successfully utilized for the determination of copper ions in real sample matrices.
Zitieren
APA
Kumar, N. (2026). A Highly Selective and Sensitive Potentiometric Sensor for Copper (II) Ions Using a Schiff Base-Derived Ionophore (E)-2 ((1H-pyrrol-2-yl) methylene amino) benzenethiol. International Journal of Scientific Research in Chemistry, 11(3), 51-63. https://doi.org/10.32628/ijsrch261136
Vancouver
Kumar N. A Highly Selective and Sensitive Potentiometric Sensor for Copper (II) Ions Using a Schiff Base-Derived Ionophore (E)-2 ((1H-pyrrol-2-yl) methylene amino) benzenethiol. International Journal of Scientific Research in Chemistry. 2026;11(3):51-63. doi:10.32628/ijsrch261136
BibTeX
@article{Kumar2026,
author = {Kumar, Narendra},
title = {A Highly Selective and Sensitive Potentiometric Sensor for Copper (II) Ions Using a Schiff Base-Derived Ionophore (E)-2 ((1H-pyrrol-2-yl) methylene amino) benzenethiol},
journal = {International Journal of Scientific Research in Chemistry},
year = {2026},
volume = {11},
number = {3},
pages = {51--63},
doi = {10.32628/ijsrch261136}
}
EUVIMED