EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Staircase and Elevator Core Wall Position on Torsional Response and Seismic Performance of Plan-Irregular Reinforced Concrete Buildings

Chethan M S, Shyam Prasad H. R, Dr. D S Sandeep Kumar

International Journal of Scientific Research in Civil Engineering · 04.07.2026 · 10 (4) · 77-91

DOI: 10.32628/ijsrce261048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Scientific Research in Civil Engineering, online erschienen am 04.07.2026. Verfasst von Chethan M S und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Plan-irregular reinforced concrete buildings experience significant seismic vulnerability due to eccentricity between the centre of mass and centre of stiffness, which induces torsional response during earthquake loading. The location of stiffness-concentrating elements, such as staircase and elevator core walls, plays an important role in controlling lateral deformation and overall seismic behaviour. This study investigates the influence of staircase and elevator core wall positions on the torsional response and seismic performance of plan-irregular reinforced concrete buildings. A parametric numerical study was carried out using ETABS v19 on ten-storey reinforced concrete building models with different plan irregularity ratios. Various configurations of staircase and elevator core walls, including central and opposite-corner locations, were analysed and compared with structures without core wall effects. Response spectrum analysis and time history analysis using earthquake ground motion data were performed according to Indian Standard provisions. The seismic performance was evaluated based on storey displacement and inter-storey drift responses. The results demonstrate that increasing plan irregularity leads to higher displacement and drift due to enhanced torsional effects. The presence and location of staircase and elevator core walls significantly influence structural behaviour by modifying stiffness distribution. Among the investigated configurations, the opposite-corner placement of staircase and elevator core walls exhibited improved seismic performance with reduced displacement and drift compared with other arrangements. The study highlights the importance of strategic core wall placement during the design of earthquake-resistant plan-irregular structures.

Zitieren

APA

S, C. M., R, S. P. H., & Kumar, D. D. S. S. (2026). Influence of Staircase and Elevator Core Wall Position on Torsional Response and Seismic Performance of Plan-Irregular Reinforced Concrete Buildings. International Journal of Scientific Research in Civil Engineering, 10(4), 77-91. https://doi.org/10.32628/ijsrce261048

Vancouver

S CM, R SPH, Kumar DDSS. Influence of Staircase and Elevator Core Wall Position on Torsional Response and Seismic Performance of Plan-Irregular Reinforced Concrete Buildings. International Journal of Scientific Research in Civil Engineering. 2026;10(4):77-91. doi:10.32628/ijsrce261048

BibTeX
@article{S2026,
  author = {S, Chethan M and R, Shyam Prasad H. and Kumar, Dr. D S Sandeep},
  title = {Influence of Staircase and Elevator Core Wall Position on Torsional Response and Seismic Performance of Plan-Irregular Reinforced Concrete Buildings},
  journal = {International Journal of Scientific Research in Civil Engineering},
  year = {2026},
  volume = {10},
  number = {4},
  pages = {77--91},
  doi = {10.32628/ijsrce261048}
}
Kostenlos starten →