EUVIMEDEUVIMED entdecken
Crossref

Unbuckling: an answer to address cuff-related challenges in urethral instrumentation with an artificial urinary sphincter

Hasan Jhaveri, Mariela Martinez-Rivera, Brent Nose, Jordan Foreman, Aaron C Lentz

Canadian Journal of Urology · 2025

DOI: 10.32604/cju.2025.068095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Canadian Journal of Urology, 2025. Verfasst von Hasan Jhaveri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Duke University School of Medicine, 40 Duke Medicine Cir, Durham, NC 27710, USA. Hauptthemen laut MEDLINE: Urinary Sphincter, Artificial, Urethra, Prosthesis Failure.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: There is limited in vivo data on the maximum safe instrument size that can be passed through an artificial urinary sphincter (AUS) cuff. While 21 French instruments are generally safe with the commonly used 4.5 cm cuff, larger instruments or smaller cuffs may require unbuckling to avoid urethral erosion. This study aimed to identify if artificial urinary sphincter cuff 'unbuckling' affects device longevity and risk of erosion. METHODS: A retrospective study of patients at a quaternary health system who underwent unbuckling was conducted. Using the Epic Clarity database and Duke Enterprise Data Unified Content Explorer (DEDUCE), we identified patients with artificial urinary sphincter (AUS) who were unbuckled during endoscopic procedures. Descriptive statistics were used to analyze patient demographics, device age at unbuckling, complications, and history of erosion, removal, or replacement. RESULTS: Eight patients were identified with a prior history of AUS unbuckling. The average age was 68 years. 75% of patients had a history of pelvic radiation. The average number of unbuckling procedures per patient was 1.62. The median device age at first unbuckling was 2.60 years. Average time to reactivation was 22.25 days, and 6 of 8 patients had their device reactivated. Two patients developed erosions requiring device removal. Neither erosion occurred within 90 days of unbuckling. The mean age of devices at the time of removal was 6.85 years. CONCLUSIONS: AUS cuff unbuckling may serve as an alternative strategy when large-caliber urethral instrumentation is required. Studies with larger patient cohorts are required to further investigate the efficacy and ideal utilization of unbuckling.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary Sphincter, ArtificialUrethraProsthesis FailureHumansRetrospective StudiesAgedMaleMiddle AgedFemale

Stichwörter der Autor:innen

artificial urinary sphincter (AUS)erosionunbucklinguncoupling

Autor:innen und Institutionen

  • Department of Urology, Duke University School of Medicine, 40 Duke Medicine Cir, Durham, NC 27710, USA.

Zitieren

APA

Jhaveri, H., Martinez-Rivera, M., Nose, B., Foreman, J., & Lentz, A. C. (2025). Unbuckling: an answer to address cuff-related challenges in urethral instrumentation with an artificial urinary sphincter. Canadian Journal of Urology. https://doi.org/10.32604/cju.2025.068095

Vancouver

Jhaveri H, Martinez-Rivera M, Nose B, Foreman J, Lentz AC. Unbuckling: an answer to address cuff-related challenges in urethral instrumentation with an artificial urinary sphincter. Canadian Journal of Urology. 2025. doi:10.32604/cju.2025.068095

BibTeX
@article{Jhaveri2025,
  author = {Jhaveri, Hasan and Martinez-Rivera, Mariela and Nose, Brent and Foreman, Jordan and Lentz, Aaron C},
  title = {Unbuckling: an answer to address cuff-related challenges in urethral instrumentation with an artificial urinary sphincter},
  journal = {Canadian Journal of Urology},
  year = {2025},
  doi = {10.32604/cju.2025.068095}
}
Kostenlos starten →