Prognostic Value of Optic Nerve Sheath Diameter in Patients after Extracorporeal Cardiopulmonary Resuscitation
Journal of Neurointensive Care · 2019
DOI: 10.32587/jnic.2019.00108 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neurointensive Care, 2019. Verfasst von Youngjin Kim und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Themen: Reanimation
Abstract (Originalsprache)
ObjectiveTo determine whether optic nerve sheath diameter (ONSD) could be used to predict neurological outcomes in patients after extracorporeal cardiopulmonary resuscitation (ECPR). MethodsThis was a retrospective and observational study of adult unconscious patients who were evaluated by brain computed tomography (CT) scan within 48 hours after ECPR between May 2010 and December 2016.ONSDs were estimated on initial brain CT.The primary outcome was neurological status upon hospital discharge assessed with Cerebral Performance Categories (CPC) scale.CPC scores of 1 and 2 indicated good neurological outcome while CPC scores of 3, 4, and 5 indicated poor neurological outcome. ResultsAmong 52 unconscious patients, survival to discharge was identified in 19 (36.5%) patients.Of these 19 survivors, 13 (25.0%)had good neurological outcome (CPC score of 1 or 2).ONSDs and their modification in the poor neurological outcome group were significantly greater than those in the good neurological outcome group (all p≤0.003).However, eyeball transverse diameter was not significantly different between the two groups (p=0.770).Analysis of the receiver operating characteristic curves for predicting poor neurological outcome showed that ONSDs had considerable predictive value (C-statistics: 0.735 to 0.812).In addition, ONSDs and their modification had similar performances for predicting poor neurological outcome. ConclusionONSDs measured with CT may be used to predict neurological outcomes of ECPR survivors.
Zitieren
APA
Kim, Y., Ryu, J., Kim, Y. O., Cho, Y. H., Yang, J. H., Lee, S., & Baek, J. S. (2019). Prognostic Value of Optic Nerve Sheath Diameter in Patients after Extracorporeal Cardiopulmonary Resuscitation. Journal of Neurointensive Care. https://doi.org/10.32587/jnic.2019.00108
Vancouver
Kim Y, Ryu J, Kim YO, Cho YH, Yang JH, Lee S, et al. Prognostic Value of Optic Nerve Sheath Diameter in Patients after Extracorporeal Cardiopulmonary Resuscitation. Journal of Neurointensive Care. 2019. doi:10.32587/jnic.2019.00108
BibTeX
@article{Kim2019,
author = {Kim, Youngjin and Ryu, Jeong-Am and Kim, Yong Oh and Cho, Yang Hyun and Yang, Jeong Hoon and Lee, Sangkil and Baek, Ji Sun},
title = {Prognostic Value of Optic Nerve Sheath Diameter in Patients after Extracorporeal Cardiopulmonary Resuscitation},
journal = {Journal of Neurointensive Care},
year = {2019},
doi = {10.32587/jnic.2019.00108}
}
EUVIMED