EUVIMEDEUVIMED entdecken
Crossref

Developing and validation of high performance liquid chromatography method for determination of carboplatin-loaded Metal-organic framework materials

Quyen Toan Pham, Han Hoang Do, Truc Thanh Nguyen, Pham Thi Thanh Huong, Linh Ho Thuy Nguyen, Tan Le Hoang Doan, Tri Minh Le

Science & Technology Development Journal - Health Sciences · 2025

DOI: 10.32508/stdjhs.v6i2.593 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science & Technology Development Journal - Health Sciences, 2025. Verfasst von Quyen Toan Pham und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Carboplatin is widely used in cancer treatments despite several adverse effects. Metal-organic framework nanoparticles (MOF) were used to load carboplatin, which could improve selectivity to cancerous tissues and control the release profile of this compound. This study aimed to develop and validate a sensitive, simple, cost-effective RP-HPLC method for quantifying carboplatin in MOF.

Methods

This study was developed and optimal different chromatographic conditions for the quantification of carboplatin-loaded MOF materials. The chosen HPLC procedure was validated throughout ICH guidelines.

Results

The chromatographic separation was achieved on an RP-C18 column (250 x 4.6 mm, 5 µm) by isocartic elution with a mobile phase consisting of methanol: potassium chloride 0.9% in a 1:1 ratio. The flow rate is 1.0 mL/min. PDA detector was used at a wavelength of 254 nm. The validation process has achieved the following criteria: system suitability, specificity, linearity, accuracy, precision, range of determination, and robustness. The method showed linearity in the 0.1-1.5 mg/mL range with R2 = 0.9998. The accuracy and %RSD were 98.03-101.37% (mean 99.98%), and 1.08, respectively.

Conclusion

This HPLC method can be used to determine the carboplatin loading and desorption efficiency of MOF materials, including ZIF-8, Zr-UiO-66, and Hf-UiO-66. The method provides a reliable analytical tool for complex MOF compositions, ensuring the safety and efficacy of novel drug delivery systems while accelerating future development in this field.

Zitieren

APA

Pham, Q. T., Do, H. H., Nguyen, T. T., Huong, P. T. T., Nguyen, L. H. T., Doan, T. L. H., & Le, T. M. (2025). Developing and validation of high performance liquid chromatography method for determination of carboplatin-loaded Metal-organic framework materials. Science & Technology Development Journal - Health Sciences. https://doi.org/10.32508/stdjhs.v6i2.593

Vancouver

Pham QT, Do HH, Nguyen TT, Huong PTT, Nguyen LHT, Doan TLH, et al. Developing and validation of high performance liquid chromatography method for determination of carboplatin-loaded Metal-organic framework materials. Science & Technology Development Journal - Health Sciences. 2025. doi:10.32508/stdjhs.v6i2.593

BibTeX
@article{Pham2025,
  author = {Pham, Quyen Toan and Do, Han Hoang and Nguyen, Truc Thanh and Huong, Pham Thi Thanh and Nguyen, Linh Ho Thuy and Doan, Tan Le Hoang and Le, Tri Minh},
  title = {Developing and validation of high performance liquid chromatography method for determination of carboplatin-loaded Metal-organic framework materials},
  journal = {Science & Technology Development Journal - Health Sciences},
  year = {2025},
  doi = {10.32508/stdjhs.v6i2.593}
}
Kostenlos starten →