EUVIMEDEUVIMED entdecken
Crossref

A computational approach for analysis of intratumoral heterogeneity and standardized uptake value in PET/CT images

Khalaf Alshamrani, Hassan A Alshamrani

Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2024

DOI: 10.3233/xst-230095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2024. Verfasst von Khalaf Alshamrani und 1 weiteren Autor:innen. Beteiligte Einrichtung: Radiological Sciences Department, College of Applied Medical Sciences, Najran University, Najran, Saudi Arabia. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Tomography, X-Ray Computed. Die Arbeit nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: By providing both functional and anatomical information from a single scan, digital imaging technologies like PET/CT and PET/MRI hybrids are gaining popularity in medical imaging industry. In clinical practice, the median value (SUVmed) receives less attention owing to disagreements surrounding what defines a lesion, but the SUVmax value, which is a semi-quantitative statistic used to analyse PET and PET/CT images, is commonly used to evaluate lesions. OBJECTIVE: This study aims to build an image processing technique with the purpose of automatically detecting and isolating lesions in PET/CT images, as well as measuring and assessing the SUVmed. METHODS: The pictures are separated into their respective lesions using mathematical morphology and the crescent region, which are both part of the image processing method. In this research, a total of 18 different pictures of lesions were evaluated. RESULTS: The findings of the study reveal that the threshold is satisfied by both the SUVmax and the SUVmed for most of the lesion types. However, in six instances, the SUVmax and SUVmed values are found to be in different courts. CONCLUSION: The new information revealed by this study needs to be further investigated to determine if it has any practical value in diagnosing and monitoring lesions. However, results of this study suggest that SUVmed should receive more attention in the evaluation of lesions in PET and CT images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyTomography, X-Ray ComputedPositron-Emission TomographyMultimodal ImagingImage Processing, Computer-AssistedFluorodeoxyglucose F18

Stichwörter der Autor:innen

PET/CT imagesdiagnosinglesionsmonitoringstandardised uptake valuetumor images

Substanzen

Fluorodeoxyglucose F18

Autor:innen und Institutionen

  • Radiological Sciences Department, College of Applied Medical Sciences, Najran University, Najran, Saudi Arabia.

Zitieren

APA

Alshamrani, K., & Alshamrani, H. A. (2024). A computational approach for analysis of intratumoral heterogeneity and standardized uptake value in PET/CT images. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-230095

Vancouver

Alshamrani K, Alshamrani HA. A computational approach for analysis of intratumoral heterogeneity and standardized uptake value in PET/CT images. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2024. doi:10.3233/xst-230095

BibTeX
@article{Alshamrani2024,
  author = {Alshamrani, Khalaf and Alshamrani, Hassan A},
  title = {A computational approach for analysis of intratumoral heterogeneity and standardized uptake value in PET/CT images},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2024},
  doi = {10.3233/xst-230095}
}
Kostenlos starten →