Set-up errors of the neck are underestimated using the overall registration frame of head and neck in IMRT for NPC
Journal of X-Ray Science and Technology · 14.09.2023 · 31 (5) · 1067-1077
DOI: 10.3233/xst-230024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, erschienen am 14.09.2023. Verfasst von Junjie Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Head and Neck Neoplasms, Nasopharyngeal Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Background
There is no standardized registration frame of cone beam CT (CBCT) in intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). The overall registration frame that covers the whole head and neck is the most commonly used CBCT registration frame for NPC patients in IMRT.
Objective
To compare the set-up errors using different registration frames of CBCT for NPC to assess the set-up errors for different region of the commonly used clinical overall registration frame.
Methods
294 CBCT images of 59 NPC patients were collected. Four registration frames were used for matching. The set-up errors were obtained using an automatic matching algorithm and then compared. The expansion margin from the clinical target volume (CTV) to the planned target volume (PTV) in the four groups was also calculated.
Results
The average range of the isocenter translation and rotation errors of four registration frames are 0.89∼2.41 mm and 0.49∼1.53°, respectively, which results in a significant difference in the set-up errors (p < 0.05). The set-up errors obtained from the overall frame are smaller than those obtained from the head, upper neck, and lower neck frames. The margin ranges of the overall, head, upper neck, and lower neck frames in three translation directions are 1.49∼2.39 mm, 1.92∼2.45 mm, 1.86∼3.54 mm and 3.02∼4.78 mm, respectively. The expansion margins calculated from the overall frame are not enough, especially for the lower neck.
Conclusion
Set-up errors of the neck are underestimated by the overall registration frame. Thus, it is important to improve the position immobilization of the neck, especially the lower neck. The margin of the target volume of the head and neck region should be expanded separately if circumstances permit.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China.
- Department of Oncology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China.
Zitieren
APA
Xu, J., Wang, T., Luo, Y., Shang, L., Mai, X., Ruan, J., Pan, X., & Chi, F. (2023). Set-up errors of the neck are underestimated using the overall registration frame of head and neck in IMRT for NPC. Journal of X-Ray Science and Technology, 31(5), 1067-1077. https://doi.org/10.3233/xst-230024
Vancouver
Xu J, Wang T, Luo Y, Shang L, Mai X, Ruan J, et al. Set-up errors of the neck are underestimated using the overall registration frame of head and neck in IMRT for NPC. Journal of X-Ray Science and Technology. 2023;31(5):1067-1077. doi:10.3233/xst-230024
BibTeX
@article{Xu2023,
author = {Xu, Junjie and Wang, Tong and Luo, Yu and Shang, Lintao and Mai, Xiuying and Ruan, Junjie and Pan, Xiaofen and Chi, Feng},
title = {Set-up errors of the neck are underestimated using the overall registration frame of head and neck in IMRT for NPC},
journal = {Journal of X-Ray Science and Technology},
year = {2023},
volume = {31},
number = {5},
pages = {1067--1077},
doi = {10.3233/xst-230024}
}
EUVIMED