EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A versatile laboratory setup for high resolution X-ray phase contrast tomography and scintillator characterization

Hanna Dierks, Philip Stjärneblad, Jesper Wallentin

Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2023

DOI: 10.3233/xst-221294 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2023. Verfasst von Hanna Dierks und 2 weiteren Autor:innen. Beteiligte Einrichtung: Lund University, Synchrotron Radiation Research and NanoLund, Lund, Sweden. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: X-ray micro-tomography (μCT) is a powerful non-destructive 3D imaging method applied in many scientific fields. In combination with propagation-based phase-contrast, the method is suitable for samples with low absorption contrast. Phase contrast tomography has become available in the lab with the ongoing development of micro-focused tube sources, but it requires sensitive and high-resolution X-ray detectors. The development of novel scintillation detectors, particularly for microscopy, requires more flexibility than available in commercial tomography systems. OBJECTIVE: We aim to develop a compact, flexible, and versatile μCT laboratory setup that combines absorption and phase contrast imaging as well as the option to use it for scintillator characterization. Here, we present details on the design and implementation of the setup. METHODS: We used the setup for μCT in absorption and propagation-based phase-contrast mode, as well as to study a perovskite scintillator. RESULTS: We show the 2D and 3D performance in absorption and phase contrast mode, as well as how the setup can be used for testing new scintillator materials in a realistic imaging environment. A spatial resolution of around 1.3μm is measured in 2D and 3D. CONCLUSIONS: The setup meets the needs for common absorption μCT applications and offers increased contrast in phase contrast mode. The availability of a versatile laboratory μCT setup allows not only for easy access to tomographic measurements, but also enables a prompt monitoring and feedback beneficial for advances in scintillator fabrication.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalX-RaysRadiographyX-Ray Microtomography

Stichwörter der Autor:innen

X-ray imaginglaboratory setupsphase contrastscintillatortomographyμCT

Autor:innen und Institutionen

  • Lund University, Synchrotron Radiation Research and NanoLund, Lund, Sweden.

Zitieren

APA

Dierks, H., Stjärneblad, P., & Wallentin, J. (2023). A versatile laboratory setup for high resolution X-ray phase contrast tomography and scintillator characterization. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-221294

Vancouver

Dierks H, Stjärneblad P, Wallentin J. A versatile laboratory setup for high resolution X-ray phase contrast tomography and scintillator characterization. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2023. doi:10.3233/xst-221294

BibTeX
@article{Dierks2023,
  author = {Dierks, Hanna and Stjärneblad, Philip and Wallentin, Jesper},
  title = {A versatile laboratory setup for high resolution X-ray phase contrast tomography and scintillator characterization},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2023},
  doi = {10.3233/xst-221294}
}
Kostenlos starten →