EUVIMEDEUVIMED entdecken
Crossref

Structure-guided computed tomography reconstruction from limited-angle projections

Changcheng Gong, Jianxun Liu

Journal of X-Ray Science and Technology · 27.01.2023 · 31 (1) · 95-117

DOI: 10.3233/xst-221256 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 31.10.2022. Verfasst von Changcheng Gong und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Tomography, X-Ray Computed. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Limited-angle computed tomography (CT) imaging is one of the common imaging problems. The reconstructed images often encounter obvious artifacts and structure degradation. In recent years, the recoverability prior of image structure has been widely explored in limited-angle CT reconstruction, and the image quality has been greatly improved. However, the artifacts and structure degradation still exist. In this study, we establish a new reconstruction model based on weighted relative structure (wRS) determined by image gradients, which serves as weights to guide image reconstruction in order to reduce artifacts and preserve structures. Then, we develop an efficient algorithm using a surrogate function to solve this model. Moreover, this method is compared with some of other popular reconstruction methods, such as anisotropic total variation method and image gradient L 0 norm minimization method and so on. Experiments on digital phantoms, real carved cheese and walnut projection are reported to demonstrate its superiority. Several quantitative indices including RMSE, PSNR, and SSIM of the reconstruction images from 90°-data of FORBILD head phantom are 0.0120, 43.52, and 0.9961. The experimental results indicate that the image obtained by our method is the closest to reference image. By comparing reconstruction images or their residual images, images reconstructed from real CT data, the experimental results of the residual images and the respective quantitative data analysis also demonstrate that the images reconstructed using our new method suffer from less artifacts and structure degradation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedTomography, X-Ray ComputedPhantoms, ImagingAlgorithmsArtifacts

Stichwörter der Autor:innen

Inverse problemanisotropic total variationcomputed tomographyimage reconstructionrelative structure

Autor:innen und Institutionen

  • School of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, China.
  • Chongqing Key Laboratory of Social Economic and Applied Statistics, Chongqing Technology and Business University, Chongqing, China.
  • School of Mathematics and Physics, Guangxi Minzu University, Nanning, China.

Zitieren

APA

Gong, C., & Liu, J. (2023). Structure-guided computed tomography reconstruction from limited-angle projections. Journal of X-Ray Science and Technology, 31(1), 95-117. https://doi.org/10.3233/xst-221256

Vancouver

Gong C, Liu J. Structure-guided computed tomography reconstruction from limited-angle projections. Journal of X-Ray Science and Technology. 2023;31(1):95-117. doi:10.3233/xst-221256

BibTeX
@article{Gong2023,
  author = {Gong, Changcheng and Liu, Jianxun},
  title = {Structure-guided computed tomography reconstruction from limited-angle projections},
  journal = {Journal of X-Ray Science and Technology},
  year = {2023},
  volume = {31},
  number = {1},
  pages = {95--117},
  doi = {10.3233/xst-221256}
}
Kostenlos starten →