EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access

The significance of different intervertebral spaces in combined spinal epidural anesthesia in cesarean section

Qing Yu, Jing Hu

Technology and Health Care · 2024

DOI: 10.3233/thc-240599 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Technology and Health Care, 2024. Verfasst von Qing Yu und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Cesarean Section, Anesthesia, Epidural, Anesthesia, Spinal. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The number of cesarean sections performed is increasing every year, and obstetric anesthesia is of great interest to physicians and research scholars because of its specificity, high risk, and high complication rate. OBJECTIVE: To investigate the effects of combined spinal epidural anesthesia (CSEA) with different intervertebral spaces during cesarean section on anesthesia effect, anesthesia onset time, anesthesia recovery time, maternal adverse reactions, and neonates. METHODS: Ninety-two women who underwent cesarean section in our hospital from September 2022 to February 2023 were selected as the study subjects and randomly divided them into two groups (group A and group B), 46 women in each group. Group A underwent CSEA via an L2-3 gap and group B underwent CSEA via an L3-4 gap puncture. The anesthesia effect, anesthesia onset time, sensory recovery time, adverse effects, and neonatal Apgar score were compared between the two groups. RESULTS: When CSEA was performed from L2-3, the anesthesia efficiency was higher, but the difference was not statistically significant. When anesthesia was performed by puncture from L2-3, the onset of anesthesia and recovery time was shorter, and the incidence of intraoperative maternal nausea and vomiting, hypotension, respiratory depression, and other adverse reactions was low with a statistically significant difference. However, the Apgar scores of the neonates in the two groups have no difference. CONCLUSIONS: When CSEA is induced via L2-3 interspace, anesthesia has a rapid onset of action, shorter recovery time, and few maternal adverse effects, without affecting the final anesthetic outcome.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cesarean SectionAnesthesia, EpiduralAnesthesia, SpinalHumansFemaleAdultPregnancyAnesthesia, ObstetricalInfant, NewbornApgar ScoreLumbar VertebraeAnesthesia Recovery Period

Stichwörter der Autor:innen

Combined spinal-epidural anesthesiacesarean sectiondifferenceintervertebral spaces

Zitieren

APA

Yu, Q., & Hu, J. (2024). The significance of different intervertebral spaces in combined spinal epidural anesthesia in cesarean section. Technology and Health Care. https://doi.org/10.3233/thc-240599

Vancouver

Yu Q, Hu J. The significance of different intervertebral spaces in combined spinal epidural anesthesia in cesarean section. Technology and Health Care. 2024. doi:10.3233/thc-240599

BibTeX
@article{Yu2024,
  author = {Yu, Qing and Hu, Jing},
  title = {The significance of different intervertebral spaces in combined spinal epidural anesthesia in cesarean section},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-240599}
}
Kostenlos starten →