Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics
Technology and Health Care · 2024
DOI: 10.3233/thc-240202 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology and Health Care, 2024. Verfasst von Simon Auer und 2 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Biomechanics, Ostbayerische Technische Hochschule Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Range of Motion, Articular. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research. METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems. RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements. CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory for Biomechanics, Ostbayerische Technische Hochschule Regensburg, Regensburg, Germany.
- Regensburg Center of Biomedical Engineering, Ostbayerische Technische Hochschule and University Regensburg, Germany.
Zitieren
APA
Auer, S., Süß, F., & Dendorfer, S. (2024). Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics. Technology and Health Care. https://doi.org/10.3233/thc-240202
Vancouver
Auer S, Süß F, Dendorfer S. Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics. Technology and Health Care. 2024. doi:10.3233/thc-240202
BibTeX
@article{Auer2024,
author = {Auer, Simon and Süß, Franz and Dendorfer, Sebastian},
title = {Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics},
journal = {Technology and Health Care},
year = {2024},
doi = {10.3233/thc-240202}
}
EUVIMED