Bi-cruciate retaining total knee arthroplasty is here to stay: A consecutive series transitioning from manual instrumentation to enabling technologies
Technology and Health Care · 2024
DOI: 10.3233/thc-231608 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology and Health Care, 2024. Verfasst von Luca Barberis und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of Turin, Turin, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Bicruciate-retaining (BCR) total knee arthroplasty (TKA) has seen renewed interest due to the potential for more natural knee kinematics with anterior cruciate ligament (ACL) retention. OBJECTIVE: The present study attempts to determine differences in the 2-year survivorship and patient-reported outcomes between two surgical strategies (traditional instrumentation versus robotics) applied to the extensive use of a modern, 2 nd generation BCR TKA design. METHODS: We performed a retrospective study with prospectively collected data of 113 patients who underwent primary TKA between 2018 and 2020 using a 2 nd generation BCR TKA implant. Patient demographics, PROMS, and intra/post-operative complications were collected. Patients were also evaluated according to the use or not of robotics. A Kaplan-Meier analysis was used to evaluate revision-free survival at follow up. RESULTS: 102 patients were enrolled: 90 received traditional surgery and 12 robotic-assisted surgery. The mean age was 68 years (SD 7.76) with an average BMI of 29.6 kg/m 2 (SD 3.56). The mean follow up (FU) was 32.4 ± 6.2 months (range 24–45 months). Survivorship at 2 years was 98% (95% CI: 92.4–99.5). Revisions/reoperations were performed for anterior cruciate ligament (ACL) tear (1/4), pain (1/4), arthrofibrosis (1/4) and acute periprosthetic joint infection (PJI) (1/4). At final FU, 92 patients (90.2%) considered themselves satisfied, showing a mean OKS of 40.6 (SD 5.1) and a mean FKS of 76.7 (SD 11.8). No differences in the outcome were found between traditional and robotic-assisted procedures. CONCLUSION: The modern BCR design evaluated in this study achieved excellent results in terms of implant survivorship, low rate of reoperation and clinical results, independently from the use of enabling technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine, University of Turin, Turin, Italy.
- Michele e Pietro Ferrero Hospital, Verduno, Italy.
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Palo Alto, CA, USA.
- SOC Ortopedia Protesica - CESAT, USL Toscana Centro, Fucecchio, Italy.
Zitieren
APA
Barberis, L., Sabatini, L., Pellegrino, A., Galletta, C., Risitano, S., Capella, M., Massè, A., Schiraldi, M., & Indelli, P. F. (2024). Bi-cruciate retaining total knee arthroplasty is here to stay: A consecutive series transitioning from manual instrumentation to enabling technologies. Technology and Health Care. https://doi.org/10.3233/thc-231608
Vancouver
Barberis L, Sabatini L, Pellegrino A, Galletta C, Risitano S, Capella M, et al. Bi-cruciate retaining total knee arthroplasty is here to stay: A consecutive series transitioning from manual instrumentation to enabling technologies. Technology and Health Care. 2024. doi:10.3233/thc-231608
BibTeX
@article{Barberis2024,
author = {Barberis, Luca and Sabatini, Luigi and Pellegrino, Andrea and Galletta, Claudia and Risitano, Salvatore and Capella, Marcello and Massè, Alessandro and Schiraldi, Marco and Indelli, Pier Francesco},
title = {Bi-cruciate retaining total knee arthroplasty is here to stay: A consecutive series transitioning from manual instrumentation to enabling technologies},
journal = {Technology and Health Care},
year = {2024},
doi = {10.3233/thc-231608}
}
EUVIMED