Multizentrische Studie

Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring

Christian Butter, Gunnar Klein, Gerian Grönefeld, Dirk Böcker, Anna Suling, Anika Buchholz, Angelika Felk, Tino Hauser, Karl Wegscheider, Dietmar Bänsch

Technology and Health Care · 2024

DOI: 10.3233/thc-230641 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Technology and Health Care, 2024. Verfasst von Christian Butter und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Heart Centre Brandenburg Bernau and Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, Ber…. Hauptthemen laut MEDLINE: Defibrillators, Implantable. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Both highly specialized heart centres and less specialized hospitals care for patients with implantable ICDs/CRT-Ds with remote monitoring. OBJECTIVE: To investigate potential differences in patient treatment according to centre’s ICD implantation volume. METHODS: Based on their 2012 ICD/CRT-D implantation volume, centres enrolled in the NORDIC ICD trial in Germany were assigned to one of three groups: high- (HV, n= 345), medium- (MV, n= 340) or low-volume (LV, n= 189). RESULTS: The HV-centres had a significant higher CRT-D proportion (41.7%; LV: 36.5%; MV: 23.2%; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001), significant shorter median procedure duration (49 min; MV: 58 min; LV: 60 min; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001) but significant longer median hospital stay (4 days; MV and LV: 3 days; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001) compared to MV- and LV-centres. The X-ray exposure was shorter in MV/HV-centres (MV: 3.4 min; HV: 3.6 min; LV: 5.5 min; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001). Only 3.5% (LV: 2.6%; HV: 3.5%; MV: 4.1%) patients received at least one delivered inappropriate shock and 2.5% (HV: 2.0%; LV: 2.6%; MV: 2.9%) patients had withheld inappropriate ICD shocks without subsequent inappropriate shock delivery within 24.5 months of median follow-up. CONCLUSION: Implantation volume-dependent differences were observed in the device selection, procedure duration and x-ray exposure duration. Remote monitoring in combination with adequate response pattern prevented imminent inappropriate shocks in all three groups.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableHumansFemaleMaleMiddle AgedAgedLength of StayGermanyHospitals, Low-VolumeHospitals, High-VolumeHeart FailureRemote Sensing Technology

Stichwörter der Autor:innen

Defibrillatorscardiac resynchronization therapyhigh-volumehome monitoringhospitalsimplantablelow-volume

Autor:innen und Institutionen

  • Department of Cardiology, Heart Centre Brandenburg Bernau and Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, Bernau, Germany.
  • Heart Center Hannover, Clinic for Cardiology and Electrophysiology, Hannover, Germany.
  • Asklepios Clinic Barmbek, Hamburg, Germany.
  • Department of Cardiology, St. Marien Hospital, Hamm, Germany.
  • University Medical Center Hamburg-Eppendorf, Institute of Medical Biometry and Epidemiology, Hamburg, Germany.
  • BIOTRONIK, Berlin, Germany.

Zitieren

APA

Butter, C., Klein, G., Grönefeld, G., Böcker, D., Suling, A., Buchholz, A., Felk, A., Hauser, T., Wegscheider, K., & Bänsch, D. (2024). Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring. Technology and Health Care. https://doi.org/10.3233/thc-230641

Vancouver

Butter C, Klein G, Grönefeld G, Böcker D, Suling A, Buchholz A, et al. Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring. Technology and Health Care. 2024. doi:10.3233/thc-230641

BibTeX
@article{Butter2024,
  author = {Butter, Christian and Klein, Gunnar and Grönefeld, Gerian and Böcker, Dirk and Suling, Anna and Buchholz, Anika and Felk, Angelika and Hauser, Tino and Wegscheider, Karl and Bänsch, Dietmar},
  title = {Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-230641}
}
Kostenlos starten →