Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring
Technology and Health Care · 2024
DOI: 10.3233/thc-230641 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Technology and Health Care, 2024. Verfasst von Christian Butter und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Heart Centre Brandenburg Bernau and Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, Ber…. Hauptthemen laut MEDLINE: Defibrillators, Implantable. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Both highly specialized heart centres and less specialized hospitals care for patients with implantable ICDs/CRT-Ds with remote monitoring. OBJECTIVE: To investigate potential differences in patient treatment according to centre’s ICD implantation volume. METHODS: Based on their 2012 ICD/CRT-D implantation volume, centres enrolled in the NORDIC ICD trial in Germany were assigned to one of three groups: high- (HV, n= 345), medium- (MV, n= 340) or low-volume (LV, n= 189). RESULTS: The HV-centres had a significant higher CRT-D proportion (41.7%; LV: 36.5%; MV: 23.2%; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001), significant shorter median procedure duration (49 min; MV: 58 min; LV: 60 min; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001) but significant longer median hospital stay (4 days; MV and LV: 3 days; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001) compared to MV- and LV-centres. The X-ray exposure was shorter in MV/HV-centres (MV: 3.4 min; HV: 3.6 min; LV: 5.5 min; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001). Only 3.5% (LV: 2.6%; HV: 3.5%; MV: 4.1%) patients received at least one delivered inappropriate shock and 2.5% (HV: 2.0%; LV: 2.6%; MV: 2.9%) patients had withheld inappropriate ICD shocks without subsequent inappropriate shock delivery within 24.5 months of median follow-up. CONCLUSION: Implantation volume-dependent differences were observed in the device selection, procedure duration and x-ray exposure duration. Remote monitoring in combination with adequate response pattern prevented imminent inappropriate shocks in all three groups.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Heart Centre Brandenburg Bernau and Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, Bernau, Germany.
- Heart Center Hannover, Clinic for Cardiology and Electrophysiology, Hannover, Germany.
- Asklepios Clinic Barmbek, Hamburg, Germany.
- Department of Cardiology, St. Marien Hospital, Hamm, Germany.
- University Medical Center Hamburg-Eppendorf, Institute of Medical Biometry and Epidemiology, Hamburg, Germany.
- BIOTRONIK, Berlin, Germany.
Zitieren
APA
Butter, C., Klein, G., Grönefeld, G., Böcker, D., Suling, A., Buchholz, A., Felk, A., Hauser, T., Wegscheider, K., & Bänsch, D. (2024). Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring. Technology and Health Care. https://doi.org/10.3233/thc-230641
Vancouver
Butter C, Klein G, Grönefeld G, Böcker D, Suling A, Buchholz A, et al. Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring. Technology and Health Care. 2024. doi:10.3233/thc-230641
BibTeX
@article{Butter2024,
author = {Butter, Christian and Klein, Gunnar and Grönefeld, Gerian and Böcker, Dirk and Suling, Anna and Buchholz, Anika and Felk, Angelika and Hauser, Tino and Wegscheider, Karl and Bänsch, Dietmar},
title = {Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring},
journal = {Technology and Health Care},
year = {2024},
doi = {10.3233/thc-230641}
}
EUVIMED