Signal Quality and Reliability of Heart Rate Measurement Using Simultaneous PPG and Inertial Data in Healthy Adults
Studies in Health Technology and Informatics · 07.05.2026
DOI: 10.3233/shti260087 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Studies in Health Technology and Informatics, erschienen am 07.05.2026. Verfasst von Katrin Hainzl und 11 weiteren Autor:innen. Beteiligte Einrichtung: University of Applied Sciences Wiener Neustadt, Wiener Neustadt, Austria. Hauptthemen laut MEDLINE: Photoplethysmography, Heart Rate, Smartphone, Signal Processing, Computer-Assisted. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Reliable estimation of heart rate and beat-to-beat intervals is essential for cardiovascular monitoring. Smartphone sensors such as photoplethysmography (PPG) and inertial measurement units (IMUs) offer accessible measurement possibilities, but their reliability depends on acquisition conditions.
Methods
In this observational pilot study, simultaneous PPG and accelerometer signals were recorded using smartphones across three acquisition configurations: single-device supine (M1), single-device seated (M2), and synchronized dual-device recordings (M3). RR intervals were derived using identical filtering and peak detection pipelines.
Results
Agreement between accelerometer- and PPG-derived RR intervals differed significantly between configurations (Kruskal–Wallis H = 15.98, p < .001). The dual-device configuration showed lower median RR agreement error (38.33 ms) compared to single-device setups (median 107 ms).
Conclusion
Acquisition configuration substantially influences agreement of smartphone-derived RR intervals. These findings highlight the importance of standardized acquisition setups for reliable smartphone-based cardiac monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Applied Sciences Wiener Neustadt, Wiener Neustadt, Austria.
- Medical University Innsbruck, Innsbruck, Austria.
- AIT Austrian Institute of Technology GmbH, Graz, Austria.
- Ludwig Boltzmann Institute for Digital Health and Prevention, Salzburg, Austria.
- Technical University Graz, Graz, Austria.
Zitieren
APA
Hainzl, K., Negm, A., Schweighofer, E., Wagner, N., Busch, A., Schreinlechner, M., Pröll, S., Pavluk, D., Baumgartner, M., Wiesmüller, F., Hayn, D., & Schreier, G. (2026). Signal Quality and Reliability of Heart Rate Measurement Using Simultaneous PPG and Inertial Data in Healthy Adults. Studies in Health Technology and Informatics. https://doi.org/10.3233/shti260087
Vancouver
Hainzl K, Negm A, Schweighofer E, Wagner N, Busch A, Schreinlechner M, et al. Signal Quality and Reliability of Heart Rate Measurement Using Simultaneous PPG and Inertial Data in Healthy Adults. Studies in Health Technology and Informatics. 2026. doi:10.3233/shti260087
BibTeX
@article{Hainzl2026,
author = {Hainzl, Katrin and Negm, Amr and Schweighofer, Eva and Wagner, Nele and Busch, Anne and Schreinlechner, Michael and Pröll, Samuel and Pavluk, Daniel and Baumgartner, Martin and Wiesmüller, Fabian and Hayn, Dieter and Schreier, Günter},
title = {Signal Quality and Reliability of Heart Rate Measurement Using Simultaneous PPG and Inertial Data in Healthy Adults},
journal = {Studies in Health Technology and Informatics},
year = {2026},
doi = {10.3233/shti260087}
}
EUVIMED