EUVIMEDEUVIMED entdecken
Open Access

A novel low-cost approach for navigated transcranial magnetic stimulation

Jakob Rodseth, Edward P Washabaugh, Chandramouli Krishnan

Restorative Neurology and Neuroscience · 21.11.2017 · 35 (6) · 601-609

DOI: 10.3233/rnn-170751 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Restorative Neurology and Neuroscience, online erschienen am 09.10.2017. Verfasst von Jakob Rodseth und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, University of Michigan Medical School, Ann Arbor, MI, USA. Hauptthemen laut MEDLINE: Brain Mapping. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcranial magnetic stimulation (TMS) is commonly used for assessing or modulating brain excitability. However, the credibility of TMS outcomes depends on accurate and reliable coil placement during stimulation. Navigated TMS systems can address this issue, but these systems are expensive for routine use in clinical and research environments.

Objective

The purpose of this study was to provide a high-quality open source framework for navigated TMS and test its reliability and accuracy using standard TMS procedures.

Methods

A navigated TMS system was created using a low-cost 3D camera system (OptiTrack Trio), which communicates with our free and open source software environment programmed using the Unity 3D gaming engine. The environment is user friendly and has functions to allow for a variety of stimulation procedures (e.g., head and coil co-registration, multiple hotspot/grid tracking, intuitive matching, and data logging). The system was then validated using a static mockup of a TMS session. The clinical utility was also evaluated by assessing the repeatability and operator accuracy when collecting motor evoked potential (MEP) data from human subjects.

Results

The system was highly reliable and improved coil placement accuracy (position error = 1.2 mm and orientation error = 0.3°) as well as the quality and consistency (ICC >0.95) of MEPs recorded during TMS.

Conclusion

These results indicate that the proposed system is a viable tool for reliable coil placement during TMS procedures, and can improve accuracy in locating the coil over a desired hotspot both within and between sessions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain MappingAlgorithmsBrainElectromyographyEvoked Potentials, MotorFeedback, SensoryHumansNeuronavigationReproducibility of ResultsTranscranial Magnetic Stimulation

Stichwörter der Autor:innen

Frameless stereotaxic systembrain stimulationco-registrationcoil trackingmotor mappingneuronavigation

Autor:innen und Institutionen

  • Department of Physical Medicine and Rehabilitation, University of Michigan Medical School, Ann Arbor, MI, USA.
  • Deparment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
  • School of Kinesiology, University of Michigan, Ann Arbor, MI, USA.

Förderung

  • NIBIB NIH HHS

Zitieren

APA

Rodseth, J., Washabaugh, E. P., & Krishnan, C. (2017). A novel low-cost approach for navigated transcranial magnetic stimulation. Restorative Neurology and Neuroscience, 35(6), 601-609. https://doi.org/10.3233/rnn-170751

Vancouver

Rodseth J, Washabaugh EP, Krishnan C. A novel low-cost approach for navigated transcranial magnetic stimulation. Restorative Neurology and Neuroscience. 2017;35(6):601-609. doi:10.3233/rnn-170751

BibTeX
@article{Rodseth2017,
  author = {Rodseth, Jakob and Washabaugh, Edward P and Krishnan, Chandramouli},
  title = {A novel low-cost approach for navigated transcranial magnetic stimulation},
  journal = {Restorative Neurology and Neuroscience},
  year = {2017},
  volume = {35},
  number = {6},
  pages = {601--609},
  doi = {10.3233/rnn-170751}
}