Comparison of PDA diameter measurements using color and 2D echocardiography in newborn infants
Journal of Neonatal-Perinatal Medicine · 28.03.2023 · 16 (1) · 137-140
DOI: 10.3233/npm-221042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neonatal-Perinatal Medicine, erschienen am 28.03.2023. Verfasst von S S Pereira. Beteiligte Einrichtung: Neonatal Unit, Homerton University Hospital NHS Foundation Trust, Homerton Row, London, UK. Hauptthemen laut MEDLINE: Ductus Arteriosus, Patent. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 9 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Patent ductus arteriosus (PDA) diameter is a frequently measured echocardiographic parameter when assessing the PDA. Though, there are recommendations to use 2D echocardiography to measure the PDA diameter, there is paucity of data on how PDA diameter compares when measured using 2D and color echocardiography. The aim of this work was to examine the bias and limits of agreement between measuring PDA diameter using color and 2D echocardiography in newborn infants. METHODS: This retrospective study examined the PDA using the high parasternal ductal view. Using colour compare, three consecutive cardiac cycles were used to measure PDA diameter at the narrowest point where the PDA joined the left pulmonary artery in both 2D and colour echocardiography by a single operator. RESULTS: The bias between PDA diameter using color and 2D echocardiography was examined in 23 infants (mean gestation: 28.7weeks). The mean (SD, 95% LoA) bias between color and 2D were 0.45(0.23, –0.005 to 0.91) mm. CONCLUSION: Color measurements exaggerated PDA diameter measurements when compared to 2D echocardiography.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neonatal Unit, Homerton University Hospital NHS Foundation Trust, Homerton Row, London, UK.
- Centre for Genomics and Child Health, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK.
Zitieren
APA
Pereira, S. S. (2023). Comparison of PDA diameter measurements using color and 2D echocardiography in newborn infants. Journal of Neonatal-Perinatal Medicine, 16(1), 137-140. https://doi.org/10.3233/npm-221042
Vancouver
Pereira SS. Comparison of PDA diameter measurements using color and 2D echocardiography in newborn infants. Journal of Neonatal-Perinatal Medicine. 2023;16(1):137-140. doi:10.3233/npm-221042
BibTeX
@article{Pereira2023,
author = {Pereira, S S},
title = {Comparison of PDA diameter measurements using color and 2D echocardiography in newborn infants},
journal = {Journal of Neonatal-Perinatal Medicine},
year = {2023},
volume = {16},
number = {1},
pages = {137--140},
doi = {10.3233/npm-221042}
}