EUVIMEDEUVIMED entdecken
Crossref

Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors

Ernst Michael Jung, Ulrich Kaiser, Wolfgang Herr, Christian Stroszczynski, Friedrich Jung

Clinical Hemorheology and Microcirculation · 2024

DOI: 10.3233/ch-249103 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Hemorheology and Microcirculation, 2024. Verfasst von Ernst Michael Jung und 4 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Carcinoma, Hepatocellular, Liver Neoplasms. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18–84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesCarcinoma, HepatocellularLiver NeoplasmsHumansContrast MediaViscosityLiverUltrasonography

Stichwörter der Autor:innen

HiFR CEUSMultimodal liver tissue imaging (M-Ref)SR CEUSUMAelastographyfat evaluationviscosity

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Interdisciplinary Ultrasound Department, Institute of Diagnostic Radiology, University Hospital Regensburg, Regensburg, Germany.
  • Clinic and Polyclinic for Internal Medicine III, University Hospital Regensburg, Regensburg, Germany.
  • Molecular Cell Biology, Institute of Biotechnology, Brandenburg University of Technology, Senftenberg, Germany.

Zitieren

APA

Jung, E. M., Kaiser, U., Herr, W., Stroszczynski, C., & Jung, F. (2024). Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors. Clinical Hemorheology and Microcirculation. https://doi.org/10.3233/ch-249103

Vancouver

Jung EM, Kaiser U, Herr W, Stroszczynski C, Jung F. Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors. Clinical Hemorheology and Microcirculation. 2024. doi:10.3233/ch-249103

BibTeX
@article{Jung2024,
  author = {Jung, Ernst Michael and Kaiser, Ulrich and Herr, Wolfgang and Stroszczynski, Christian and Jung, Friedrich},
  title = {Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors},
  journal = {Clinical Hemorheology and Microcirculation},
  year = {2024},
  doi = {10.3233/ch-249103}
}
Kostenlos starten →