EUVIMEDEUVIMED entdecken
Crossref

Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation

Manuel Stern, Sven Baasen, Patricia Wischmann, Theresa Herbrand, Johanna Schremmer, Oliver Maier, Marc Stern, Christian Jung, Christian Heiss, Malte Kelm, Roberto Sansone, Lucas Busch

Clinical Hemorheology and Microcirculation · 2024

DOI: 10.3233/ch-232051 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Hemorheology and Microcirculation, 2024. Verfasst von Manuel Stern und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, Heinrich-Heine University, Duesseldorf, Germany. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Data on the effect of transcatheter aortic valve implantation (TAVI) on peripheral microcirculation are limited. OBJECTIVE: The aim of this study is to evaluate peripheral microvascular tissue saturation (StO 2 ) before and after TAVI in relation to central and peripheral hemodynamics, cardiac and renal function. METHODS: In this single-center prospective study, patients with severe aortic stenosis (sAS) scheduled for TAVI or cardiac catheterization (control) were assessed before and up to five days after the procedure. Cardiac function including cardiac output (CO) was assessed by echocardiography. Brachial (bBP) and central blood pressure (cBP), ankle brachial index (ABI), and parameters of arterial stiffness, including augmentation pressure (AP) and augmentation index adjusted for heart rate (AIx@HR75) were measured to assess hemodynamic changes. StO 2 was measured in all extremities using a near-infrared spectroscopy (NIRS) camera. Renal function was measured by creatinine levels. RESULTS: 26 patients underwent TAVI and 11 patients served as control. Cardiac output was significantly increased, whereas hemodynamic parameters and peripheral StO 2 were significantly decreased after TAVI. At follow-up, StO 2 returned to baseline values. Changes in StO 2 were negatively related to creatinine levels. CONCLUSION: Transcatheter aortic valve implantation causes a temporary decrease in microvascular tissue saturation that is associated with renal function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisHumansMaleFemaleProspective StudiesAgedAged, 80 and overMicrocirculationHemodynamicsOxygen Saturation

Stichwörter der Autor:innen

Microcirculationmicrovascular tissue saturationnear-infrared spectroscopytranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, Heinrich-Heine University, Duesseldorf, Germany.
  • Department of Clinical and Experimental Medicine, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK.
  • Department of Vascular Medicine, Surrey and Sussex NHS Healthcare Trust, Redhill, UK.
  • Cardiovascular Research Institute Duesseldorf (CARID), Duesseldorf, Germany.

Zitieren

APA

Stern, M., Baasen, S., Wischmann, P., Herbrand, T., Schremmer, J., Maier, O., Stern, M., Jung, C., Heiss, C., Kelm, M., Sansone, R., & Busch, L. (2024). Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation. Clinical Hemorheology and Microcirculation. https://doi.org/10.3233/ch-232051

Vancouver

Stern M, Baasen S, Wischmann P, Herbrand T, Schremmer J, Maier O, et al. Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation. Clinical Hemorheology and Microcirculation. 2024. doi:10.3233/ch-232051

BibTeX
@article{Stern2024,
  author = {Stern, Manuel and Baasen, Sven and Wischmann, Patricia and Herbrand, Theresa and Schremmer, Johanna and Maier, Oliver and Stern, Marc and Jung, Christian and Heiss, Christian and Kelm, Malte and Sansone, Roberto and Busch, Lucas},
  title = {Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation},
  journal = {Clinical Hemorheology and Microcirculation},
  year = {2024},
  doi = {10.3233/ch-232051}
}
Kostenlos starten →