Initial ablation radio predicting volume reduction from microwave ablation of benign thyroid nodules
Clinical Hemorheology and Microcirculation · 2023
DOI: 10.3233/ch-231699 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Hemorheology and Microcirculation, 2023. Verfasst von Xincai Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Ultrasound, Affiliated Hospital of Jiangsu University, Zhenjiang, China. Hauptthemen laut MEDLINE: Thyroid Nodule, Radiofrequency Ablation, Catheter Ablation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Our research sought to investigate the relationship between initial ablation ratio (IAR) and internal composition of benign thyroid nodules treated by microwave ablation (MWA). MATERIALS AND METHODS: Patients who underwent MWA at the Affiliated Hospital of Jiangsu University from January 2018 to December 2022 were enrolled in our research. All the patients were followed up for at least one year. We analyzed the relationship between IAR at 1 month of solid nodules (solid >90%), predominantly solid nodules (90% >solid > 75%), mixed solid alongside cystic nodules (75% >solid > 50%) as well as volume reduction rate (VRR) at 1, 3, 6 and 12 months follow-up. OBJECTIVE: The mean IAR of the solid nodules (solid >90%) was 94.32±7.87%,#x0025;, that of the predominantly solid nodules (90% >solid > 75%) and mixed solid alongside cystic nodules (75% >solid > 50%) were 86.51±6.66% and 75.19±4.97%,#x0025;, respectively. Almost all the thyroid nodules were significantly decreased in size after MWA. After 12 months of MWA treatment, the average volume of the aforementioned thyroid nodules decreased from 8.69±8.79 to 1.84±3.11 ml, 10.94±9.07 to 2.58±3.34 ml, 9.92±6.27 to 0.25±0.42 ml, respectively. The mean symptom and cosmetic scores of the nodules showed significant (p < 0.000) improvement. The rates of the complications or side effects of MWA against the above-mentioned nodule types were 8.3% (3/36), 3.2% (1/31) and 0% (0/36), respectively. CONCLUSIONS: The application of the IAR to quantify the success rate of thyroid nodule microwaves in the short term demonstrated that IAR was related to the internal components of the nodule. Although the IAR was not high when the thyroid component was mixed solid and cystic nodules (75% >solid > 50%), the final therapeutic effect was still satisfactory.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Ultrasound, Affiliated Hospital of Jiangsu University, Zhenjiang, China.
Zitieren
APA
Wu, X., Zhang, X., Wang, K., Zhao, S., Shang, M., Duan, R., Zhang, Z., & Chen, B. (2023). Initial ablation radio predicting volume reduction from microwave ablation of benign thyroid nodules. Clinical Hemorheology and Microcirculation. https://doi.org/10.3233/ch-231699
Vancouver
Wu X, Zhang X, Wang K, Zhao S, Shang M, Duan R, et al. Initial ablation radio predicting volume reduction from microwave ablation of benign thyroid nodules. Clinical Hemorheology and Microcirculation. 2023. doi:10.3233/ch-231699
BibTeX
@article{Wu2023,
author = {Wu, Xincai and Zhang, Xin and Wang, Keke and Zhao, Shuangshuang and Shang, Mengyuan and Duan, Ran and Zhang, Zheng and Chen, Baoding},
title = {Initial ablation radio predicting volume reduction from microwave ablation of benign thyroid nodules},
journal = {Clinical Hemorheology and Microcirculation},
year = {2023},
doi = {10.3233/ch-231699}
}
EUVIMED