EUVIMEDEUVIMED entdecken
Crossref

Dynamic amplification factors of girder and cables of extradosed bridges during sudden cable failure

Homer Buelvas, José M. Benjumea, Gustavo Chio

Bridge Structures · 09.12.2021 · 17 (3-4) · 101-110

DOI: 10.3233/brs-210189 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bridge Structures, erschienen am 09.12.2021. Verfasst von Homer Buelvas und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rupture of a cable in cable-supported bridges is an accidental condition that should be considered during the design phase due the impact that this situation could have on the structural safety of the bridge and users. For that reason, design guidelines suggest carrying out a pseudo-static analysis where the failing cable is replaced by a load of the same magnitude as the pre-rupture tension but applied in the opposite direction and multiplied by a dynamic amplification factor (DAF) between 1.5 and 2.0. Previous studies in cable-stayed bridges have shown that the pseudo-static approach may not be suitable. Due to the wide use of extradosed bridges in infrastructure projects around the world, a computational analysis was performed in this investigation to estimate the dynamic amplification factors of extradosed bridge girders and cables when sudden failure of an extradosed cable occurs. The main goal of the study is to determine whether the pseudo-static approach suggested in the guidelines is acceptable. Linear response history analyses were performed by using computational models of extradosed bridges in which the girder stiffness and the suspension (lateral or central) and cable layout (fan or harp) of the cables were modified. From the analysis, the DAFs were calculated and compared to those recommended in the design guidelines. The calculated DAFs for the axial forces and bending moment in the girder of the bridges and for the axial forces in the extradosed cables were smaller than 2.0. However, in some cases the DAF for shear forces were higher than 2.0, especially when the girder stiffness was relatively low. The results indicate that the recommendations of the design guidelines are adequate for extradosed bridges, which is a result of the relatively high stiffness of the girder and low inclination of extradosed cables. Despite this, response history analyses like the one performed in this study are recommended to assess the response of the bridge under cable breakage.

Zitieren

APA

Buelvas, H., Benjumea, J. M., & Chio, G. (2021). Dynamic amplification factors of girder and cables of extradosed bridges during sudden cable failure. Bridge Structures, 17(3-4), 101-110. https://doi.org/10.3233/brs-210189

Vancouver

Buelvas H, Benjumea JM, Chio G. Dynamic amplification factors of girder and cables of extradosed bridges during sudden cable failure. Bridge Structures. 2021;17(3-4):101-110. doi:10.3233/brs-210189

BibTeX
@article{Buelvas2021,
  author = {Buelvas, Homer and Benjumea, José M. and Chio, Gustavo},
  title = {Dynamic amplification factors of girder and cables of extradosed bridges during sudden cable failure},
  journal = {Bridge Structures},
  year = {2021},
  volume = {17},
  number = {3-4},
  pages = {101--110},
  doi = {10.3233/brs-210189}
}
Kostenlos starten →