EUVIMEDEUVIMED entdecken
Crossref

Anatomical cup implantation assisted with dynamic 3D planning improves functional outcomes in primary total hip arthroplasty: A retrospective study

Zhenhui Sun, Nan Li, Zhi Yang, Wenhui Zhang, Jie Liu

Journal of Back and Musculoskeletal Rehabilitation · 2024

DOI: 10.3233/bmr-230004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Back and Musculoskeletal Rehabilitation, 2024. Verfasst von Zhenhui Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Tianjin Hospital of Tianjin University, Tianjin, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis. Die Arbeit nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Anatomical cup implantation is a promising approach in primary total hip arthroplasty (THA) and improves functional outcomes. OBJECTIVE: We aimed to evaluate the cup position and functional outcomes in primary THA with preoperative dynamic 3D planning. METHODS: We retrospectively reviewed 54 hips in 48 patients who underwent primary THA with anatomical cup implantation (mean follow-up time: 52 months). Cup positions were evaluated based on patient-specific morphology, the acetabular fossa and the combined anteversion test. Functional outcomes were assessed after THA. The paired-sample t-test was performed for surgical and contralateral native hips among 42 patients who underwent unilateral THA. RESULTS: Two hips suffered intraoperative trochanteric fracture, but no hip dislocations occurred. No patients reported groin or thigh pain, and all patients were capable of deep squatting and one-leg standing. The mean Harris hip score, WOMAC score, and physical SF-36 score were 94.46 ± 6.16, 10.41 ± 3.62, and 95.19 ± 8.74, respectively. Except for acetabular offset, THA restored biomechanics to those of contralateral native hip, including cup anteversion, abduction, femoral offset and acetabular height (P> 0.05). CONCLUSION: This study provided evidence for the application of anatomical cup implantation assisted with dynamic 3D planning in primary THA, which restored morphology and improved functional outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisHumansRetrospective StudiesAcetabulumFemur

Stichwörter der Autor:innen

3D planningTotal hip arthroplastyacetabular cup implantationretrospective study

Autor:innen und Institutionen

  • Department of Orthopaedics, Tianjin Hospital of Tianjin University, Tianjin, China.
  • School of Biomedical Engineering, Capital Medical University, Beijing, China.
  • Department of Orthopaedics, People's Hospital of Gansu Province, Lanzhou, Gansu, China.

Zitieren

APA

Sun, Z., Li, N., Yang, Z., Zhang, W., & Liu, J. (2024). Anatomical cup implantation assisted with dynamic 3D planning improves functional outcomes in primary total hip arthroplasty: A retrospective study. Journal of Back and Musculoskeletal Rehabilitation. https://doi.org/10.3233/bmr-230004

Vancouver

Sun Z, Li N, Yang Z, Zhang W, Liu J. Anatomical cup implantation assisted with dynamic 3D planning improves functional outcomes in primary total hip arthroplasty: A retrospective study. Journal of Back and Musculoskeletal Rehabilitation. 2024. doi:10.3233/bmr-230004

BibTeX
@article{Sun2024,
  author = {Sun, Zhenhui and Li, Nan and Yang, Zhi and Zhang, Wenhui and Liu, Jie},
  title = {Anatomical cup implantation assisted with dynamic 3D planning improves functional outcomes in primary total hip arthroplasty: A retrospective study},
  journal = {Journal of Back and Musculoskeletal Rehabilitation},
  year = {2024},
  doi = {10.3233/bmr-230004}
}
Kostenlos starten →