EUVIMEDEUVIMED entdecken
Crossref

Evaluation of alveolar bone density around abutments in fixed prostheses designed according to prosthetic principles using CBCT: a retrospective study

Bülent Kadir Tartuk, Mustafa Caner Akgül, Eyyüp Altıntaş

Journal of Health Sciences and Medicine · 20.07.2026 · 9 (4) · 1112-1118

DOI: 10.32322/jhsm.1921927 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Health Sciences and Medicine, online erschienen am 20.07.2026. Verfasst von Bülent Kadir Tartuk und 2 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben. Gefördert von: None.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The aim of this retrospective study was to evaluate temporal changes in the alveolar bone density surrounding abutment teeth in fixed prosthetic restorations designed according to prosthetic principles, using normalized gray values obtained from cone-beam computed tomography (CBCT).

Methods

Among 211 patients who had undergone at least two CBCT scans within the last decade (2016-2025), 15 patients who met the inclusion criteria were selected. A total of 22 fixed dental bridges and 55 abutment teeth were evaluated, with a mean actual follow-up duration of 15.9\pm 6.3 months (range: 8.3-31.5 months). For each abutment, a 2-mm circumferential peri-radicular bone zone was segmented using 3D Slicer software. To minimize variability arising from different imaging parameters, gray values were normalized based on the theoretical -1000 HU reference of the maxillary sinus air cavity. To account for intra-subject clustering, data were analyzed using a linear mixed-effects model (LMM) and Pearson correlation analysis. A significance level of p

Förderung

  • None

Zitieren

APA

Tartuk, B. K., Akgül, M. C., & Altıntaş, E. (2026). Evaluation of alveolar bone density around abutments in fixed prostheses designed according to prosthetic principles using CBCT: a retrospective study. Journal of Health Sciences and Medicine, 9(4), 1112-1118. https://doi.org/10.32322/jhsm.1921927

Vancouver

Tartuk BK, Akgül MC, Altıntaş E. Evaluation of alveolar bone density around abutments in fixed prostheses designed according to prosthetic principles using CBCT: a retrospective study. Journal of Health Sciences and Medicine. 2026;9(4):1112-1118. doi:10.32322/jhsm.1921927

BibTeX
@article{Tartuk2026,
  author = {Tartuk, Bülent Kadir and Akgül, Mustafa Caner and Altıntaş, Eyyüp},
  title = {Evaluation of alveolar bone density around abutments in fixed prostheses designed according to prosthetic principles using CBCT: a retrospective study},
  journal = {Journal of Health Sciences and Medicine},
  year = {2026},
  volume = {9},
  number = {4},
  pages = {1112--1118},
  doi = {10.32322/jhsm.1921927}
}
Kostenlos starten →