EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

References for electrophysiological measurements for intraoperative verification of placement for several types of CI electrodes

Dziemba, Oliver C., Mir Salim, Parwis, Müller, Alexander

GMS Zeitschrift für Audiologie – Audiological Acoustics · 10.09.2024 · 6 (Doc14)

DOI: 10.3205/zaud000049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift GMS Zeitschrift für Audiologie – Audiological Acoustics, erschienen am 10.09.2024. Verfasst von Dziemba und 5 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quality assured implantation and fitting of cochlear implants (CI) is based on several pre-, intra- and postoperative audiological measurement methods. Verification of CI electrode position is an important part of the intraoperative measurements during the implantation. Postoperative electrode localization checks are usually based on CT scan and conventional X-Ray and lead to an additional radiation exposure for the patient. Spread of Excitation measurement (SOE) is an alternative intraoperative electrophysiological method avoiding especially postoperative imaging techniques. Several studies have shown that this objective method can detect a “tip foldover” and is therefore suitable as a fast and cost efficient procedure to detect electrode displacements during the procedure. For evaluation this method needs standardized measurement protocols and electrode specific normal values. In our study this was performed, analyzed and discussed in 37 patients using different electrodes.

Schlagwörter

cochlear implantsintraoperative measurementsspread of excitationposition controscreeningCochlea-Implantateintraoperative MessungenSpread of ExcitationLagekontrolleScreening

Zitieren

APA

Dziemba, C., O., Salim, M., Parwis, Müller, & Alexander (2024). References for electrophysiological measurements for intraoperative verification of placement for several types of CI electrodes. GMS Zeitschrift für Audiologie – Audiological Acoustics, 6(Doc14). https://doi.org/10.3205/zaud000049

Vancouver

Dziemba, C. O, Salim M, Parwis, Müller, Alexander. References for electrophysiological measurements for intraoperative verification of placement for several types of CI electrodes. GMS Zeitschrift für Audiologie – Audiological Acoustics. 2024;6(Doc14). doi:10.3205/zaud000049

BibTeX
@article{Dziemba2024,
  author = {Dziemba and C., Oliver and Salim, Mir and Parwis and Müller and Alexander},
  title = {References for electrophysiological measurements for intraoperative verification of placement for several types of CI electrodes},
  journal = {GMS Zeitschrift für Audiologie – Audiological Acoustics},
  year = {2024},
  volume = {6},
  number = {Doc14},
  doi = {10.3205/zaud000049}
}
Kostenlos starten →