Untersuchung des Einflusses der Störgeräuschrichtung auf das Sprachverstehen mit Richtmikrofonsystem
GMS Zeitschrift für Audiologie – Audiological Acoustics · 30.06.2021 · 1-1
DOI: 10.3205/zaud000017 ↗Kurz gefasst
Fachartikel in der Zeitschrift GMS Zeitschrift für Audiologie – Audiological Acoustics, erschienen am 30.06.2021. Verfasst von Kerner und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Within the scope of the hearing aid fitting, measurements of speech recognition in noise are carried out to validate the success of the fitting. The guideline for hearing-aid provision in Germany specifies the minimum improvement to be achieved, but not the spatial measurement condition of speech and noise signals. To estimate the influence of the spatial conditions, speech recognition was examined in its dependence on different noise directions and the respective improvement in signal-to-noise ratio (SNR) when using a typical directional microphone in hearing aids. Therefore, a virtual acoustic environment was created using the “Toolbox for Acoustic Scene Creation and Rendering” (TASCAR). In combination with Head-Related Transfer Functions and the Master Hearing Aid (MHA), a listening situation, as realistic as possible, was simulated via headphones. The measurements were performed by young participants with normal hearing. The MHA included only a directional microphone implementation. The noise was presented from the directions 0°, 90°, 180°, the direction ±45° as specified in DIN EN ISO 8253-3, ±135°, and from all directions simultaneously (diffuse). The speech signal was always presented from the frontal direction. The Oldenburg sentence test (OLSA) and the Freiburg monosyllabic speech test (FBE) were used. For OLSA, speech recognition thresholds for scores of 50% (SRT50) were measured for each condition (six noise directions, each with and without MHA). For FBE, speech recognition was determined as a percentage score at different fixed SNR for each condition (five noise directions, without ±45°). For OLSA, the SNR improvement due to the directional microphone was also calculated. The results showed that, regardless of the use of the directional microphone, the noise direction had an influence on speech recognition. The perceptual improvements in speech recognition were consistent with the directional SNR improvements measured by the directional microphone system. Based on these results with young participants without hearing impairment, further studies with participants with hearing impairment should follow to discuss the missing standardization of speech and noise direction in the guideline for hearing-aid provision in Germany.
Schlagwörter
Zitieren
APA
Kerner, M., Winkler, A., Holube, & I. (2021). Untersuchung des Einflusses der Störgeräuschrichtung auf das Sprachverstehen mit Richtmikrofonsystem. GMS Zeitschrift für Audiologie – Audiological Acoustics, 1-1. https://doi.org/10.3205/zaud000017
Vancouver
Kerner, M., Winkler, A., Holube, I.. Untersuchung des Einflusses der Störgeräuschrichtung auf das Sprachverstehen mit Richtmikrofonsystem. GMS Zeitschrift für Audiologie – Audiological Acoustics. 2021:1-1. doi:10.3205/zaud000017
BibTeX
@article{Kerner2021,
author = {Kerner and M. and Winkler and A. and Holube and I.},
title = {Untersuchung des Einflusses der Störgeräuschrichtung auf das Sprachverstehen mit Richtmikrofonsystem},
journal = {GMS Zeitschrift für Audiologie – Audiological Acoustics},
year = {2021},
pages = {1--1},
doi = {10.3205/zaud000017}
}
EUVIMED