Registrierung stationärer Potenziale des auditorischen Systems (ASSR) in Echtzeit mit einem Lock-in Verstärker
GMS Zeitschrift für Audiologie – Audiological Acoustics · 19.05.2021 · 1-1
DOI: 10.3205/zaud000015 ↗Kurz gefasst
Fachartikel in der Zeitschrift GMS Zeitschrift für Audiologie – Audiological Acoustics, erschienen am 19.05.2021. Verfasst von Mühler und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Human auditory steady-state responses (ASSRs) are represented in the Electroencephalogram (EEG) by single spectral lines at the stimulus repetition rate. To increase the small signal-to noise ratio of these responses, commercial ASSR systems usually average several segments of the EEG signal prior to be converted from the time domain into the frequency domain. The averaging process however does not allow for a recording of ASSR in real time. This paper describes an experimental setup which replaces averaging and frequency analysis by a lock-in amplifier. Lock-in amplifiers are widely used in experimental physics to extract small signals of known frequency from an extremely noisy background. A lock-in amplifier multiplies the (noisy) input signal by a reference signal. Subsequent integration with a time constant of a few seconds results in a DC signal. In our setup, with a reference signal at the same frequency as the stimulus repetition rate, the DC output is proportional to the ASSR amplitude. Auditory steady-state responses were evoked in one normal hearing female adult by presenting wide-band chirp stimuli at 40 Hz repetition rate and 50 dB nHL presentation level through an insert earphone. The amplified and band pass filtered EEG signal was fed to the input channel of a Stanford Research Type 830 lock-in amplifier. A reference signal phase locked to the stimulus was fed to the amplifiers reference input. The DC output was maximized by manually shifting the phase of the reference signal. A Digital Multimeter (Keysight DMM34460A) and a Data Acquisition Application (Keysight BenchVue) were used to record the time course of the DC output proportional to the ASSR amplitude. Switching the acoustical stimulus on and off periodically, the DC output follows the response amplitude in real time. Typical examples for time constants of 1 s and 3 s are presented. This paper presents a feasibility analysis of a recording setup for auditory steady-state responses using a lock-in amplifier. The proposed method could be of some interest for intraoperative monitoring of the auditory nerve during implantation of middle ear protheses, neurosurgical procedures, and for brain-computer interfaces (BCI).
Schlagwörter
Zitieren
APA
Mühler, & Roland (2021). Registrierung stationärer Potenziale des auditorischen Systems (ASSR) in Echtzeit mit einem Lock-in Verstärker. GMS Zeitschrift für Audiologie – Audiological Acoustics, 1-1. https://doi.org/10.3205/zaud000015
Vancouver
Mühler, Roland. Registrierung stationärer Potenziale des auditorischen Systems (ASSR) in Echtzeit mit einem Lock-in Verstärker. GMS Zeitschrift für Audiologie – Audiological Acoustics. 2021:1-1. doi:10.3205/zaud000015
BibTeX
@article{Mhler2021,
author = {Mühler and Roland},
title = {Registrierung stationärer Potenziale des auditorischen Systems (ASSR) in Echtzeit mit einem Lock-in Verstärker},
journal = {GMS Zeitschrift für Audiologie – Audiological Acoustics},
year = {2021},
pages = {1--1},
doi = {10.3205/zaud000015}
}
EUVIMED