Comparative evaluation of the aggregate index of systemic inflammation (AISI) and its modified version for early detection of central line-associated bloodstream infection: a pilot study using machine learning techniques
GMS Hygiene and Infection Control · 30.06.2026 · 21 (Doc52) · Doc52
DOI: 10.3205/dgkh000661 ↗Kurz gefasst
Fachartikel in der Zeitschrift GMS Hygiene and Infection Control, erschienen am 30.06.2026. Verfasst von Gargee Anand und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology, All India Institute of Medical Sciences, Patna, Bihar, India. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Katheterassoziierte Infektionen, Künstliche Intelligenz in der Pflege
Abstract (Originalsprache)
Background
Central line-associated bloodstream infections (CLABSI) are a common and serious problem in critically ill patients; their early detecting is challenging. This study evaluated the predictive ability of the aggregate index of systemic inflammation (AISI) and its modified form for early identification of CLABSI within two calendar days following central line insertion, using a machine learning approach.
Method
We conducted an analysis of patients who received central line insertion. Inflammatory indices were calculated using laboratory parameters obtained on second day post-insertion. Four machine learning algorithms were applied to evaluate their predictive performance for early CLABSI detection.
Results
Among 234 patients who met the inclusion criteria, 39 were confirmed CLABSI cases. We found both indices significantly elevated in the CLABSI group. Modified AISI demonstrated the strongest performance using XGBoost, with the highest area under the ROC curve (0.99), 97% sensitivity and 98% specificity, indicating its potential as the better early screening marker for CLABSI than AISI.
Conclusion
Both AISI and modified AISI demonstrated strong predictive value for early CLABSI detection, being both accessible and cost-effective. Modified AISI outperformed AISI in predictive performance. These findings support the need for the prospective validation of the modified AISI before clinical implementation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Microbiology, All India Institute of Medical Sciences, Patna, Bihar, India.
- Department of Microbiology, All India Institute of Medical Sciences, Deoghar, Jharkhand, India.
- Department of Biochemistry, All India Institute of Medical Sciences, Patna, Bihar, India.
- All India Institute of Medical Sciences, Patna, Bihar, India.
Zitieren
APA
Anand, G., Priyadarshi, K., Kumari, B., Tiewsoh, J. B. A., & Lahariya, R. (2026). Comparative evaluation of the aggregate index of systemic inflammation (AISI) and its modified version for early detection of central line-associated bloodstream infection: a pilot study using machine learning techniques. GMS Hygiene and Infection Control, 21(Doc52), Doc52. https://doi.org/10.3205/dgkh000661
Vancouver
Anand G, Priyadarshi K, Kumari B, Tiewsoh JBA, Lahariya R. Comparative evaluation of the aggregate index of systemic inflammation (AISI) and its modified version for early detection of central line-associated bloodstream infection: a pilot study using machine learning techniques. GMS Hygiene and Infection Control. 2026;21(Doc52):Doc52. doi:10.3205/dgkh000661
BibTeX
@article{Anand2026,
author = {Anand, Gargee and Priyadarshi, Ketan and Kumari, Bandana and Tiewsoh, Jutang Babat Ain and Lahariya, Rijhul},
title = {Comparative evaluation of the aggregate index of systemic inflammation (AISI) and its modified version for early detection of central line-associated bloodstream infection: a pilot study using machine learning techniques},
journal = {GMS Hygiene and Infection Control},
year = {2026},
volume = {21},
number = {Doc52},
pages = {Doc52},
doi = {10.3205/dgkh000661}
}
EUVIMED