EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An innovative method to prevent infection when measuring the arterial blood gas SpO2 saturation

Seda Şahan, Sevil Güler, Eliz Geçtan, Hakan Aygün

GMS Hygiene and Infection Control · 17.04.2024 · 19 (Doc18) · Doc18

DOI: 10.3205/dgkh000473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift GMS Hygiene and Infection Control, erschienen am 17.04.2024. Verfasst von Seda Şahan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Izmir Bakircay University, Health Sciences Faculty, Nursing Department, İzmir, Turkey. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Patients are hospitalized for extended periods, particularly in intensive care units (ICUs). As a result, the saturation probe (pulse oximeter) remains attached for an extended period and microorganisms can grow in the wet environment. If the pulse oximeters are not reprocessed, cross-infection may occur. The literature contains several studies in which gloves were used for the measurement while various SpO2 (peripheral arterial oxygen saturation) measurements were compared with each other. However, such comparisons have yet to be made with the results of arterial blood gas SpO2 measurements by pulse oximeter, considered as the gold standard. The present study aimed to compare arterial blood gas values with the fingertip saturation measurement performed by having adult patients wear gloves of different colors, one after the other, on their fingers and determining the effect of the differently colored gloves (transparent, white, black, light blue) on saturation values.

Methods

The study was conducted on 54 patients in an ICU. Intra-arterial blood gas SpO2 results were measured. Oxygen saturation was measured while the patient 1. did not wear gloves and 2. sequentially wore a series of gloves of different colors. Paired t-test, correlation analysis, and Bland Altman charts were used to evaluate the results.

Results

The mean SpO2% value of the participants’ intra-arterial blood gas measurements was 97.76±2.04. The mean SpO2% value obtained from the measurements of the fingers with a transparent glove was 0.43 points lower than the mean SpO2% value of the intra-arterial blood gas measurements (t=0.986, p=0.61). The mean SpO2% value obtained from the measurements of the fingers with a white glove was 0.93 points lower than the mean SpO2% value of the intra-arterial blood gas measurements (t=1.157, p=0.093).

Conclusion

Of the measurements performed with a glove, the mean SpO2% value obtained from the measurements of the fingers with a transparent glove was more consistent with the mean SpO2% value of the intra-arterial blood gas measurements than measurement of the fingers without a glove.

Schlagwörter

Stichwörter der Autor:innen

cross infectiongloveintra-arterial blood gas measurementoxygen saturationpulse oximeter

Autor:innen und Institutionen

  • Izmir Bakircay University, Health Sciences Faculty, Nursing Department, İzmir, Turkey.
  • Erciyes University, Health Sciences Faculty, Nursing Department, Kayseri, Turkey.
  • İzmir Bakircay University Cigli Education and Research Hospital, Anaesthesia, İzmir,Turkey.

Zitieren

APA

Şahan, S., Güler, S., Geçtan, E., & Aygün, H. (2024). An innovative method to prevent infection when measuring the arterial blood gas SpO2 saturation. GMS Hygiene and Infection Control, 19(Doc18), Doc18. https://doi.org/10.3205/dgkh000473

Vancouver

Şahan S, Güler S, Geçtan E, Aygün H. An innovative method to prevent infection when measuring the arterial blood gas SpO2 saturation. GMS Hygiene and Infection Control. 2024;19(Doc18):Doc18. doi:10.3205/dgkh000473

BibTeX
@article{ahan2024,
  author = {Şahan, Seda and Güler, Sevil and Geçtan, Eliz and Aygün, Hakan},
  title = {An innovative method to prevent infection when measuring the arterial blood gas SpO2 saturation},
  journal = {GMS Hygiene and Infection Control},
  year = {2024},
  volume = {19},
  number = {Doc18},
  pages = {Doc18},
  doi = {10.3205/dgkh000473}
}
Kostenlos starten →