Optimized Personalized Contrast Agent Dosing for Abdominal CT: Bridging Quantitative Theory with Clinical Practice
Journal of Medical Imaging · 30.06.2026 · 9 (1) · 65-73
DOI: 10.31916/sjmi2026-01-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Imaging, online erschienen am 30.06.2026. Verfasst von Ken Karl Zhang und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Purpose
Personalized administration of iodinated contrast media has become an increasingly important strategy for improving diagnostic consistency while minimizing unnecessary contrast exposure in abdominal computed tomography (CT). Conventional protocols based on fixed contrast volumes or body weight alone often fail to account for substantial interindividual variations in anthropometric and hemodynamic characteristics, resulting in heterogeneous enhancement and inefficient contrast utilization. This study aimed to develop and clinically validate a quantitative patient-specific contrast dosing algorithm that integrates body weight, height, and heart rate to achieve standardized portal venous enhancement while substantially reducing contrast medium volume. Materials and Methods: A retrospective analysis was performed using 5,000 consecutive abdominal CT examinations, from which 370 representative datasets were selected for quantitative evaluation. A multivariate linear regression model incorporating body weight, height, and heart rate was developed to predict the individualized contrast volume required to achieve a target hepatic enhancement of 125 Hounsfield Units (HU). Image quality was evaluated using quantitative attenuation measurements and Visual Grading Analysis (VGA). Automated bolus triggering and optimized scan delay timing were incorporated to ensure consistent portal venous phase acquisition. Diagnostic performance, contrast reduction, and workflow feasibility were analyzed. The mean hepatic enhancement remained consistently close Results: The proposed personalized dosing algorithm reduced contrast media volume by approximately 30% compared with conventional fixed-dose protocols while maintaining equivalent diagnostic image quality. The mean hepatic enhancement remained consistently close to the predefined target of 125 HU across different body habitus categories. VGA demonstrated preserved diagnostic confidence with median scores of 4 or higher in all evaluated cases. Optimization of portal venous phase timing to approximately 102 seconds further improved enhancement uniformity and minimized interpatient variability. The combination of individualized contrast dosing and optimized scan timing significantly enhanced protocol reproducibility without compromising diagnostic performance.
Conclusion
A quantitative personalized contrast dosing strategy incorporating anthropometric and hemodynamic variables provides a practical framework for precision abdominal CT imaging. The proposed algorithm substantially reduces contrast medium utilization while maintaining high diagnostic image quality and standardized hepatic enhancement. Integration of automated triggering and future artificial intelligence–based protocol optimization may further improve imaging consistency, patient safety, and cost-effectiveness, representing an important step toward precision imaging in modern radiology.
Zitieren
APA
Zhang, K. K., Lee, H., Kim, J., & Lee, G. (2026). Optimized Personalized Contrast Agent Dosing for Abdominal CT: Bridging Quantitative Theory with Clinical Practice. Journal of Medical Imaging, 9(1), 65-73. https://doi.org/10.31916/sjmi2026-01-7
Vancouver
Zhang KK, Lee H, Kim J, Lee G. Optimized Personalized Contrast Agent Dosing for Abdominal CT: Bridging Quantitative Theory with Clinical Practice. Journal of Medical Imaging. 2026;9(1):65-73. doi:10.31916/sjmi2026-01-7
BibTeX
@article{Zhang2026,
author = {Zhang, Ken Karl and Lee, Hwunjae and Kim, Jooyeon and Lee, Giljae},
title = {Optimized Personalized Contrast Agent Dosing for Abdominal CT: Bridging Quantitative Theory with Clinical Practice},
journal = {Journal of Medical Imaging},
year = {2026},
volume = {9},
number = {1},
pages = {65--73},
doi = {10.31916/sjmi2026-01-7}
}
EUVIMED