Clinical efficacy of Diode Laser in Oral PyogenicGranuloma

Ayman Najim, Tahrir Aldelaimi

Iraqi Journal of Laser · 15.06.2026 · 25 (1) · 75-83

DOI: 10.31900/ijl.v251.557 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Iraqi Journal of Laser, online erschienen am 15.06.2026. Verfasst von Ayman Najim und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oral pyogenic granuloma (PG) is a benign but very vascular lesion that causes discomfort and bleeding.Conventional surgical excision is effective but has a high recurrence rate and postoperative pain. Diode laserexcision is a less invasive procedure that offers precise tissue removal and better hemostasis. Our Objective is toevaluate the safety and efficacy of diode laser excision for the treatment of oral pyogenic granuloma. A total ofsixteen patients (mean age 39.3; age range 15 - 74 years; 11 males and 5 females) with de novo oral PG wereenrolled and all lesions were removed under local anesthesia using a continuous 1.5 W 980 nm diode laser withminimal bleeding, without the need for sutures and a 0.5 mm safety margin was kept. Patients were evaluated at oneweek and three weeks after surgery and on postoperative days one and three. Wound healing, hemostasis, pain andsatisfaction were all assessed on every visit. The excised tissues were confirmed histopathologically. The diode laserprovided better control over intraoperative bleeding, as any small amount of bleeding was easily controlled. Painsettled rapidly, as the majority of patients were comfortable by day three and completely pain-free within one week.The healing process progressed quickly, with satisfactory to excellent results by one week and full recovery bythree. Nearly all patients expressed high satisfaction at the last follow-up. Diode laser excision is a safe and efficienttreatment for oral PG that provides excellent hemostasis, less discomfort following surgery, quick healing, and highpatient satisfaction. These findings corroborate the reliable clinical results of diode laser excision in current standardtreatment.

Zitieren

APA

Najim, A., & Aldelaimi, T. (2026). Clinical efficacy of Diode Laser in Oral PyogenicGranuloma. Iraqi Journal of Laser, 25(1), 75-83. https://doi.org/10.31900/ijl.v251.557

Vancouver

Najim A, Aldelaimi T. Clinical efficacy of Diode Laser in Oral PyogenicGranuloma. Iraqi Journal of Laser. 2026;25(1):75-83. doi:10.31900/ijl.v251.557

BibTeX
@article{Najim2026,
  author = {Najim, Ayman and Aldelaimi, Tahrir},
  title = {Clinical efficacy of Diode Laser in Oral PyogenicGranuloma},
  journal = {Iraqi Journal of Laser},
  year = {2026},
  volume = {25},
  number = {1},
  pages = {75--83},
  doi = {10.31900/ijl.v251.557}
}
Kostenlos starten →