An Efficient Noise Removal on sEMG Signals: Wearable Textile- Based Electrodes Application
Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi · 20.04.2026 · 34 (1) · 2098-2112
DOI: 10.31796/ogummf.1773406 ↗Kurz gefasst
Fachartikel in der Zeitschrift Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi, online erschienen am 20.04.2026. Verfasst von Cennet Ceylan und 1 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben.
Abstract (Originalsprache)
The use of textile-based sensors has increased significantly in recent years, and wearable textile-based sensors have become superior interfaces for bio-signal sensing. Surface electromyography (sEMG), a widely used method for recording the electrical activity of muscles, has been used with textile-based electrodes. However, sEMG signals can be corrupted by various noises, interference and artifacts. In this study, an effective noise reduction algorithm has been developed on sEMG signals obtained from textile-based electrodes. The algorithm introduces a novel hybrid scheme which includes wavelet thresholding to wavelet neural network. The performance of the proposed algorithm is analyzed with real data and compared with existing algorithms. It is shown that the proposed algorithm achieves remarkable performance in noise reduction and the results obtained with the proposed algorithm are superior to the results obtained with the state-of-the-art existing algorithms. The optimum performance results of the proposed algorithm are observed as a mean square error (MSE) value of 0.0014, a root means square error (RMSE) of 0.0374, and a correlation coefficient (r) value of 0.97 with sEMG signals obtained by textile-based electrodes. It is seen that the proposed algorithm significantly improves the quality of sEMG signals for wearable applications thus it is believed to be a potential candidate on the signal acquisition of wearable technologies.
Zitieren
APA
Ceylan, C., & Özbay, S. (2026). An Efficient Noise Removal on sEMG Signals: Wearable Textile- Based Electrodes Application. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi, 34(1), 2098-2112. https://doi.org/10.31796/ogummf.1773406
Vancouver
Ceylan C, Özbay S. An Efficient Noise Removal on sEMG Signals: Wearable Textile- Based Electrodes Application. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi. 2026;34(1):2098-2112. doi:10.31796/ogummf.1773406
BibTeX
@article{Ceylan2026,
author = {Ceylan, Cennet and Özbay, Serkan},
title = {An Efficient Noise Removal on sEMG Signals: Wearable Textile- Based Electrodes Application},
journal = {Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi},
year = {2026},
volume = {34},
number = {1},
pages = {2098--2112},
doi = {10.31796/ogummf.1773406}
}
EUVIMED