EUVIMEDEUVIMED entdecken
Crossref

DEVELOPED AND VALIDATED STABILITYINDICATINGMETHOD USING RP-HPLC TO QUANTITATIVELYDETERMINE RELUGOLIX IN TABLETS

P. P Rao, P Ruthvika, B. C Naidu, V Rajesh, KNVC Lakshmi

RASAYAN Journal of Chemistry · 2026 · 19 (02) · 974-984

DOI: 10.31788/rjc.2026.1929643 ↗

Kurz gefasst

Fachartikel in der Zeitschrift RASAYAN Journal of Chemistry, 2026. Verfasst von P. P Rao und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A quantitative approach for determining and validating the dosage form of Relugolix tablets was developed utilisingRP-HPLC. The equipment utilised includes HPLC systems equipped with Photodiode Array (PDA) and Ultraviolet (UV) detectors, specifically from Waters or Agilent manufacturers. A reversed-phase Octadecyl HPLCcolumn(YMC Triart C18) having a particle size of 5 microns with dimensions of 150mm x 4.6mm (inside diameter) hasbeen employed for routine analysis (Part number: TA12S05-1546WT). Two mobile phases were used: A&B. Mobile phase A is a 70:30% v/v ratio of 10 millimolar mono potassium phosphate buffer (pH 8.30) and acetonitrile. On the other hand, mobile phase B is of 100% methanol. Gradient program operates at a flow rate of 1.0 mL/min, with an injection volume of 20 µL, with the column oven temperature of 30°C, temperature 5°C, and detectionwavelength of 236 nm. A diluent comprising 90% trifluoroacetic acid (0.1%) in methanol and 10%water by volumewas utilised for sample extraction. The established stability-indicating method determined a concentration rangeof 50-150 μg/mL and an intraclass correlation coefficient of 1.00. Spectral purity is validated using forced degradationtests. The specificity (placebo and degradation interference), recovery, precision, linearity, ruggedness, robustness, filter validation, and solution stability have been conducted in accordance with ICH Q2 and Q14 guidelines. Thismethod has been successfully developed and assessed to quantitatively determine Relugolix in tablet formulationsfor release and stability analysis in a quality control laboratory.

Zitieren

APA

Rao, P. P., Ruthvika, P., Naidu, B. C., Rajesh, V., & Lakshmi, K. (2026). DEVELOPED AND VALIDATED STABILITYINDICATINGMETHOD USING RP-HPLC TO QUANTITATIVELYDETERMINE RELUGOLIX IN TABLETS. RASAYAN Journal of Chemistry, 19(02), 974-984. https://doi.org/10.31788/rjc.2026.1929643

Vancouver

Rao PP, Ruthvika P, Naidu BC, Rajesh V, Lakshmi K. DEVELOPED AND VALIDATED STABILITYINDICATINGMETHOD USING RP-HPLC TO QUANTITATIVELYDETERMINE RELUGOLIX IN TABLETS. RASAYAN Journal of Chemistry. 2026;19(02):974-984. doi:10.31788/rjc.2026.1929643

BibTeX
@article{Rao2026,
  author = {Rao, P. P and Ruthvika, P and Naidu, B. C and Rajesh, V and Lakshmi, KNVC},
  title = {DEVELOPED AND VALIDATED STABILITYINDICATINGMETHOD USING RP-HPLC TO QUANTITATIVELYDETERMINE RELUGOLIX IN TABLETS},
  journal = {RASAYAN Journal of Chemistry},
  year = {2026},
  volume = {19},
  number = {02},
  pages = {974--984},
  doi = {10.31788/rjc.2026.1929643}
}
Kostenlos starten →