Six-Mode Non-Ideal State-Space Modeling and Cascade Type III-PI Control for a Three-Phase Interleaved Bidirectional DC-DC Converter
International Journal of Robotics and Control Systems · 28.05.2026 · 6 (3) · 2365-2390
DOI: 10.31763/ijrcs.v6i3.2746 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Robotics and Control Systems, online erschienen am 28.05.2026. Verfasst von Duc Ngoc Nguyen und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Integrating energy storage systems requires reliable bidirectional DC-DC converters; however, controlling three-phase interleaved topologies remains challenging due to the Right-Half-Plane (RHP) zero in boost mode and distinct minimum-phase dynamics in buck mode. This paper proposes a mode-decoupled cascade Type III-PI control strategy for a synchronous three-phase interleaved bidirectional DC-DC converter. The main contribution is a six-mode non-ideal state-space averaged model derived for the non-overlapping switching region (D 1/3 in boost mode and D 2/3 in buck mode), combined with a tailored cascade control architecture. The model explicitly incorporates inductor ESR, capacitor ESR, and MOSFET on-state resistance, while complementary PWM enforces continuous conduction mode and eliminates diode conduction, resulting in a strictly linearized plant with reduced conduction losses. The outer Type III compensator is synthesized using the K-factor method, enabling closed-form pole-zero placement and explicit phase margin design. The boost crossover frequency is set to 3 kHz (approximately one-ninth of the 26.1 kHz RHP zero), ensuring compliance with the non-minimum-phase bandwidth constraint, while the buck crossover is set to 7 kHz. Frequency-domain analysis confirms robust stability with phase margins of 75° and gain margins exceeding 15.3 dB in boost mode. In addition, three independent PI current controllers achieve phase current sharing within 1% under ±20% inductance mismatch. Processor-in-the-Loop (PIL) validation on the TMS320F28379D demonstrates a deterministic execution time of 2.5 µs per control cycle (25.5% CPU utilization at 100 kHz), confirming the feasibility of real-time implementation on cost-optimized digital controllers for bidirectional energy storage applications.
Zitieren
APA
Nguyen, D. N., & Nguyen, D. T. (2026). Six-Mode Non-Ideal State-Space Modeling and Cascade Type III-PI Control for a Three-Phase Interleaved Bidirectional DC-DC Converter. International Journal of Robotics and Control Systems, 6(3), 2365-2390. https://doi.org/10.31763/ijrcs.v6i3.2746
Vancouver
Nguyen DN, Nguyen DT. Six-Mode Non-Ideal State-Space Modeling and Cascade Type III-PI Control for a Three-Phase Interleaved Bidirectional DC-DC Converter. International Journal of Robotics and Control Systems. 2026;6(3):2365-2390. doi:10.31763/ijrcs.v6i3.2746
BibTeX
@article{Nguyen2026,
author = {Nguyen, Duc Ngoc and Nguyen, Dzung Tien},
title = {Six-Mode Non-Ideal State-Space Modeling and Cascade Type III-PI Control for a Three-Phase Interleaved Bidirectional DC-DC Converter},
journal = {International Journal of Robotics and Control Systems},
year = {2026},
volume = {6},
number = {3},
pages = {2365--2390},
doi = {10.31763/ijrcs.v6i3.2746}
}