EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

High-Reliability Two-H-Bridge Single-Phase Current Source Inverter Using Switching-Cell Structure

Tuan Do, Honnyong Cha

International Journal of Robotics and Control Systems · 01.05.2026 · 6 (3) · 1757-1776

DOI: 10.31763/ijrcs.v6i3.2626 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Robotics and Control Systems, online erschienen am 01.05.2026. Verfasst von Tuan Do und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a new, highly reliable, two-H-bridge (2HB current source inverter. By incorporating a switching-cell structure into the proposed topology, the switching overlap interval can be significantly reduced or eliminated. Therefore, the output current total harmonic distortion (THD) is reduced to 2.5% and 2.7% for il1 and il2, respectively, while the proposed inverter achieves an efficiency of 87.1% at 650 W. In addition, the capacitors embedded in the switching-cell network mitigate the dv/dt stress on the power devices and suppress overvoltage under open-circuit conditions, thereby further enhancing the overall reliability of the inverter. Switching-cell (SC) structures reduce overlapping during switching by creating an alternative current path during the transient phase. Specifically, capacitors integrated into the SC network temporarily maintain the load current when one group of switches is off and before the other group of switches is fully on. Thanks to this "buffering" mechanism, the need for simultaneous conduction between switches is significantly minimized. As a result, the switching process is smoother, stress on components is reduced, and dv/dt is limited, thereby contributing to the reduction of electromagnetic interference (EMI). The proposed inverter is capable of flexible operation under two different modes, including common frequency (CF) mode and differential frequency (DF) mode. In CF mode, both outputs are controlled to operate at the same base frequency, ensuring synchronization in power delivery. Conversely, in DF mode, each output can be set to operate at separate base frequencies, allowing the system to meet more independent and flexible control requirements. To evaluate and verify the operating principle, simulations were performed on the PSIM platform, in which the proposed structure was compared to a traditional single-phase H-bridge current-source inverter (2HB-CSI). In addition, a 650 W prototype was built and checked under real-world conditions to verify the system's performance. The experimental results obtained were further compared with conventional 2HB-CSI configurations as well as other dual-output current-source inverter structures. The comparison showed that the proposed structure achieved higher efficiency, improved output current quality, and enhanced operational reliability. Thanks to these advantages, the proposed inverter has broad application potential in many fields, including open-winding two-phase induction motor drives, smart grid systems, and grid-connected photovoltaic systems.

Zitieren

APA

Do, T., & Cha, H. (2026). High-Reliability Two-H-Bridge Single-Phase Current Source Inverter Using Switching-Cell Structure. International Journal of Robotics and Control Systems, 6(3), 1757-1776. https://doi.org/10.31763/ijrcs.v6i3.2626

Vancouver

Do T, Cha H. High-Reliability Two-H-Bridge Single-Phase Current Source Inverter Using Switching-Cell Structure. International Journal of Robotics and Control Systems. 2026;6(3):1757-1776. doi:10.31763/ijrcs.v6i3.2626

BibTeX
@article{Do2026,
  author = {Do, Tuan and Cha, Honnyong},
  title = {High-Reliability Two-H-Bridge Single-Phase Current Source Inverter Using Switching-Cell Structure},
  journal = {International Journal of Robotics and Control Systems},
  year = {2026},
  volume = {6},
  number = {3},
  pages = {1757--1776},
  doi = {10.31763/ijrcs.v6i3.2626}
}
Kostenlos starten →