Cardiac tamponade in a newborn caused by a peripherally inserted central catheter: case report
einstein (São Paulo) · 2025
DOI: 10.31744/einstein_journal/2025rc0634 ↗Kurz gefasst
Fallbericht in der Zeitschrift einstein (São Paulo), 2025. Verfasst von Carolina Tenfen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitário do Oeste do Paraná, Universidade Estadual do Oeste do Paraná, Cascavel, PR, Brazil. Hauptthemen laut MEDLINE: Cardiac Tamponade, Catheterization, Peripheral, Catheterization, Central Venous. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
This article describes the occurrence of cardiac tamponade in a premature newborn after the use of a peripherally inserted central catheter at a university hospital in Brazil. Pericardiocentesis was performed, the catheter was repositioned using radiography, and minimal residual pericardial effusion was confirmed using echocardiography. The patient showed good progress and was discharged from the hospital on day 47 of life without any complications related to the event. Therefore, although adverse events may occur following the insertion of peripherally inserted central catheters, imaging examinations and exclusion diagnoses have a positive impact on clinical outcomes. This study emphasizes the importance of a multidisciplinary team for monitoring and managing adverse events and optimizing the care of critically ill newborns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Hospital Universitário do Oeste do Paraná, Universidade Estadual do Oeste do Paraná, Cascavel, PR, Brazil.
- Universidade de São Paulo, São Paulo, SP, Brazil.
- Universidade Estadual do Oeste do Paraná, Cascavel, PR, Brazil.
- Universidade Estadual do Oeste do Paraná, Foz do Iguaçu, PR, Brazil.
Zitieren
APA
Tenfen, C., Casacio, G. D. M., Silva, M. F. M. D., Barreto, G. M. S., Zilly, A., & Silva, R. M. M. D. (2025). Cardiac tamponade in a newborn caused by a peripherally inserted central catheter: case report. einstein (São Paulo). https://doi.org/10.31744/einstein_journal/2025rc0634
Vancouver
Tenfen C, Casacio GDM, Silva MFMD, Barreto GMS, Zilly A, Silva RMMD. Cardiac tamponade in a newborn caused by a peripherally inserted central catheter: case report. einstein (São Paulo). 2025. doi:10.31744/einstein_journal/2025rc0634
BibTeX
@article{Tenfen2025,
author = {Tenfen, Carolina and Casacio, Gabriela Dominicci de Melo and Silva, Maria Fernanda Munhak da and Barreto, Graziely Masotti Scalabrin and Zilly, Adriana and Silva, Rosane Meire Munhak da},
title = {Cardiac tamponade in a newborn caused by a peripherally inserted central catheter: case report},
journal = {einstein (São Paulo)},
year = {2025},
doi = {10.31744/einstein_journal/2025rc0634}
}
EUVIMED