Precision Diffusion-Weighted Imaging of Head and Neck Squamous Cell Carcinoma
American Journal of Neuroradiology · 2025
DOI: 10.3174/ajnr.a9026 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Neuroradiology, 2025. Verfasst von Gloria J Guzmán Pérez-Carrillo und 11 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology (G.J.G.P.-C., W.W., R.R., M.R., D.M., M.P., T.A., H.A.), Washington University in St. Louis, St. Louis, MO guzman.gl…. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Head and Neck Neoplasms, Carcinoma, Squamous Cell, Image Interpretation, Computer-Assisted. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NCI, NIH/NCI Cancer Center.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: Head and neck squamous cell carcinoma (HNSCC) represents a serious global health burden, with over 890,000 new cases annually and approximately 450,000 related deaths worldwide. Our study aims to optimize DWI sequences for the head and neck and determine reproducibility metrics values for ADC, allowing clinicians to distinguish between genuine physiologic changes and measurement errors. MATERIALS AND METHODS: We optimized the head and neck DWI protocol using Qualitative Initiative Biomarker Alliance (QIBA)-recommended parameters, high 2000 b-value, Zoom-IT technology, and a polyvinylpyrrolidone phantom calibration. Twenty-six biopsy-proved patients with HNSCC underwent pretreatment "coffee-break" test-retest DWI scans on a Siemens 3T Vida MRI scanner. ADC values were extracted from 46/51 segmented tumor regions (either tumor mass or metastatic lymphadenopathy), and reproducibility measures were assessed using the within-subject coefficient of variation (wCV), repeatability coefficient, and intraclass correlation coefficient (ICC). Bland-Altman plots and correlation analyses were used to evaluate measurement precision. Both manual segmentation by 2 expert neuroradiologists and semiautomated methods of segmentation were utilized. RESULTS: Out of 51 identified tumor masses, 46 were included in the final analysis. The Bland-Altman plot revealed minimal bias in ADC values between test-retest scans. The calculated 5.2-5.4% wCV resulted in a repeatability coefficient of 14.4%. The ICC between test and retest measurements was 0.8-0.83, indicating good test-retest reliability. The Dice score between the 2 expert readers for all parameters indicated excellent agreement between segmentations performed by different readers, with values of 0.991 for the test measurement and 0.976 for the retest measurement. CONCLUSIONS: Our findings support the use of an optimized DWI protocol for accurate and reproducible ADC quantification in HNSCC, which is comparable with or better than the percent repeatability coefficient derived from QIBA profiles for breast, liver, and prostate, though it is inferior to those for the brain. Further quantitative imaging biomarker Stage 2-type profile research is necessary to refine imaging parameters, improve reproducibility markers, and establish DWI as a clinical standard for evaluating HNSCC tumor recurrence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- From the Department of Radiology (G.J.G.P.-C., W.W., R.R., M.R., D.M., M.P., T.A., H.A.), Washington University in St. Louis, St. Louis, MO guzman.gloria@wustl.edu.
- From the Department of Radiology (G.J.G.P.-C., W.W., R.R., M.R., D.M., M.P., T.A., H.A.), Washington University in St. Louis, St. Louis, MO.
- Division of Public Health, Department of Surgery and Siteman Cancer Center (J.L., S.W.), Washington University in St. Louis, St. Louis, MO.
- GlaxoSmithKline and QMIC (M.B.), Chicago, IL.
- Department of Radiology (D.M.), University of Michigan, Ann Arbor, MI.
- Departments of Medical Physics and Radiology, Memorial Sloan Kettering Cancer Center (A.S.-D.), New York, New York.
ORCID-Profile: Gloria J Guzmán Pérez-Carrillo, Rachel Reed, Shuang Wu, Dariya Malyarenko
Förderung
- NCI NIH HHS
- NCI
- NIH/NCI Cancer Center
- FUJIFILM Healthcare Americas Corporation RSNA seed grant
Zitieren
APA
Guzmán Pérez-Carrillo, G. J., Wang, W., Liu, J., Reed, R., Wu, S., Rahmani, M., Boss, M., Malyarenko, D., Shukla-Dave, A., Parsons, M., Andrews, T., & An, H. (2025). Precision Diffusion-Weighted Imaging of Head and Neck Squamous Cell Carcinoma. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a9026
Vancouver
Guzmán Pérez-Carrillo GJ, Wang W, Liu J, Reed R, Wu S, Rahmani M, et al. Precision Diffusion-Weighted Imaging of Head and Neck Squamous Cell Carcinoma. American Journal of Neuroradiology. 2025. doi:10.3174/ajnr.a9026
BibTeX
@article{GuzmnPrezCarrillo2025,
author = {Guzmán Pérez-Carrillo, Gloria J and Wang, Wenshang and Liu, Jingxia and Reed, Rachel and Wu, Shuang and Rahmani, Maryam and Boss, Michael and Malyarenko, Dariya and Shukla-Dave, Amita and Parsons, Matthew and Andrews, Trevor and An, Hongyu},
title = {Precision Diffusion-Weighted Imaging of Head and Neck Squamous Cell Carcinoma},
journal = {American Journal of Neuroradiology},
year = {2025},
doi = {10.3174/ajnr.a9026}
}
EUVIMED