Photon-Counting Detector CT for Lenticulostriate Arteries: Comparison with Energy-Integrating Detector CT and Reconstruction Mode Optimization
American Journal of Neuroradiology · 2026
DOI: 10.3174/ajnr.a8917 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift American Journal of Neuroradiology, 2026. Verfasst von Wentian Tang und 7 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology (W.T., W.L., Y.Z., D.J., S.L., G.L.), Geriatric Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, C…. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Basal Ganglia Cerebrovascular Disease, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: Lenticulostriate arteries (LSAs) are micro but clinically critical perforating vessels that remain difficult to visualize using conventional techniques. This study aimed to conduct a preliminary comparison of the visualization of LSAs in head and neck CTA with photon-counting detector CT (PCD-CT) with 4 reconstruction modes. MATERIALS AND METHODS: This retrospective study included patients who underwent head and neck CTA with PCD-CT between January 2024 and May 2024 and those who underwent CTA with energy-integrating detector CT (EID-CT) between September 2023 and May 2024. The images were reconstructed in 4 modes for the PCD-CT group and 1 mode for the EID-CT group. The image quality was evaluated, and the LSAs were visualized by using subjective evaluations and quantitative assessments. The Friedman test was used to compare the characteristics of the 4 reconstruction modes. RESULTS: The PCD-CT group comprised 56 patients (average age 65 ± 14 years; 28 men), and the EID-CT group comprised 28 patients (average age, 64 ± 12 years; 14 men). In the PCD-CT group, the 0.2-mm slice-thickness threshold 3D mode displayed the highest counts of LSAs (right side: 4.00 [range, 3.00-4.00]; left side: 4.00 [range, 3.00-4.00]) and the longest LSAs (right side: 23.33 ± 4.86 mm; left side: 24.18 ± 4.51 mm). The 0.4-mm slice-thickness vascular spectral postprocessing mode obtained higher subjective evaluation scores. Furthermore, the PCD-CT group exhibited a higher count of LSAs, longer LSA lengths, and superior image quality than the EID-CT group. CONCLUSIONS: PCD-CT achieves better visualization of LSAs and image quality than EID-CT and therefore constitutes an important method for observing LSAs in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- From the Department of Radiology (W.T., W.L., Y.Z., D.J., S.L., G.L.), Geriatric Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China.
- Siemens Healthineers CT Collaboration (J.C., Y.G.), Shanghai, China.
- From the Department of Radiology (W.T., W.L., Y.Z., D.J., S.L., G.L.), Geriatric Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China hnldls@163.com.
- Department of Radiology (G.L.), Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
ORCID-Profile: Wentian Tang, Jiliang Chen, Guangming Lu
Zitieren
APA
Tang, W., Li, W., Zhao, Y., Chen, J., Ge, Y., Jin, D., Luo, S., & Lu, G. (2026). Photon-Counting Detector CT for Lenticulostriate Arteries: Comparison with Energy-Integrating Detector CT and Reconstruction Mode Optimization. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a8917
Vancouver
Tang W, Li W, Zhao Y, Chen J, Ge Y, Jin D, et al. Photon-Counting Detector CT for Lenticulostriate Arteries: Comparison with Energy-Integrating Detector CT and Reconstruction Mode Optimization. American Journal of Neuroradiology. 2026. doi:10.3174/ajnr.a8917
BibTeX
@article{Tang2026,
author = {Tang, Wentian and Li, Wenjing and Zhao, Yane and Chen, Jiliang and Ge, Yingqian and Jin, Dongsheng and Luo, Song and Lu, Guangming},
title = {Photon-Counting Detector CT for Lenticulostriate Arteries: Comparison with Energy-Integrating Detector CT and Reconstruction Mode Optimization},
journal = {American Journal of Neuroradiology},
year = {2026},
doi = {10.3174/ajnr.a8917}
}