Evaluation of Vestibular Schwannoma Size across Time: How Well Do the Experts Perform and What Can Be Improved?
American Journal of Neuroradiology · 2025-06 · 46 (6) · 1249-1254
DOI: 10.3174/ajnr.a8614 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Neuroradiology, online erschienen am 05.12.2024. Verfasst von Girish Bathla und 9 weiteren Autor:innen. Beteiligte Einrichtung: From the Division of Neuroradiology, Department of Radiology (G.B., J.C.B., S.A.M., P.F., J.I.L.), Mayo Clinic, Rochester, Minnesota. Hauptthemen laut MEDLINE: Neuroma, Acoustic, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Clinical Competence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: 2D linear measurements are often used in routine clinical practice during vestibular schwannoma (VS) follow-up, primarily due to wider availability and ease of use. We sought to determine the radiologist's performance compared with 3D-volumetry, along with the impact of the number of linear measurements, slice thickness, and tumor volumes on these parameters. MATERIALS AND METHODS: Specificity and accuracy estimates and 95% confidence intervals were calculated for the entire cohort and subgroups on the basis of volumes ( 800 mm3), slice thickness (≤1.5 mm or >1.5 mm), and number of linear dimensions measured in the radiology report (0-1 or 2-3). RESULTS: There was weak agreement between the radiologist's inference and VS volumetry (0.45; 95% CI. 0.41-00.53). Agreement was lower when 0-1 tumor dimension was measured (0.29; 95% CI, 0.21-0.42), for smaller tumors of 1.5 mm (0.36; 95% CI, 0.25-0.46). The reader sensitivity was modest (0.49-0.54), while the accuracy for detecting ≤ ±25% interval change was weak (0.32-0.38). Reader performance trended toward improvement with thin-section imaging, measurement of 2-3 VS dimensions, and larger tumors. CONCLUSIONS: In routine practice, radiologists show poor agreement with volumetric results and sensitivity to detect interval change and overall poor accuracy for volumetric changes of ≤ ± 25% in volume. In the absence of volumetric measurements, radiologists need to be more diligent when evaluating interval changes in VS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- From the Division of Neuroradiology, Department of Radiology (G.B., J.C.B., S.A.M., P.F., J.I.L.), Mayo Clinic, Rochester, Minnesota.
- Department of Radiology (P.M.M.), UT Health, San Antonio, San Antonio, Texas.
- Division of Neuroradiology (N.S., A.A.), Department of Radiology, Mayo Clinic, Jacksonville, Florida Soni.neetu@mayo.edu.
- Biomedical Statistics and Informatics (M.J.), Mayo Clinic, Rochester, Minnesota.
- Division of Neuroradiology (N.S., A.A.), Department of Radiology, Mayo Clinic, Jacksonville, Florida.
- Department of Otolaryngology-Head and Neck Surgery (M.L.C.), Mayo Clinic, Rochester, Minnesota.
ORCID-Profile: Girish Bathla, Neetu Soni, Mathew Johnson, John C Benson, Steven A Messina, Paul Farnsworth, Amit Agarwal, Matthew L Carlson, John I Lane
Zitieren
APA
Bathla, G., Mehta, P. M., Soni, N., Johnson, M., Benson, J. C., Messina, S. A., Farnsworth, P., Agarwal, A., Carlson, M. L., & Lane, J. I. (2025). Evaluation of Vestibular Schwannoma Size across Time: How Well Do the Experts Perform and What Can Be Improved?. American Journal of Neuroradiology, 46(6), 1249-1254. https://doi.org/10.3174/ajnr.a8614
Vancouver
Bathla G, Mehta PM, Soni N, Johnson M, Benson JC, Messina SA, et al. Evaluation of Vestibular Schwannoma Size across Time: How Well Do the Experts Perform and What Can Be Improved?. American Journal of Neuroradiology. 2025;46(6):1249-1254. doi:10.3174/ajnr.a8614
BibTeX
@article{Bathla2025,
author = {Bathla, Girish and Mehta, Parv M and Soni, Neetu and Johnson, Mathew and Benson, John C and Messina, Steven A and Farnsworth, Paul and Agarwal, Amit and Carlson, Matthew L and Lane, John I},
title = {Evaluation of Vestibular Schwannoma Size across Time: How Well Do the Experts Perform and What Can Be Improved?},
journal = {American Journal of Neuroradiology},
year = {2025},
volume = {46},
number = {6},
pages = {1249--1254},
doi = {10.3174/ajnr.a8614}
}
EUVIMED