Initial Experiences with the Trenza Embolization Device for the Treatment of Wide-Neck Intracranial Aneurysms: A 12-Patient Case Series
American Journal of Neuroradiology · 2024
DOI: 10.3174/ajnr.a8153 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift American Journal of Neuroradiology, 2024. Verfasst von Rahul Raj und 1 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Neurosurgery (R.R.), Helsinki University Hospital and University of Helsinki, Helsinki, Finland rahul.raj@hus.fi. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Embolization, Therapeutic, Endovascular Procedures, Aneurysm, Ruptured. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Helsinki University Hospital.
Abstract (Originalsprache)
The Trenza embolization device is a frame coil implant with flow-disruption properties and is a new alternative to treat challenging mid-to-large-sized broad-neck bifurcation or sidewall aneurysms. We conducted an observational single-center retrospective study of 12 consecutive patients treated for 10 unruptured and 2 ruptured 6- to 12-mm broad-neck bifurcation or sidewall aneurysms with the Trenza device during 2022-2023. The median patient age was 64 years (interquartile range, 59-70 years), 58% were women, the median largest aneurysm diameter was 9.6 mm (interquartile range, 7.5-11.9 mm), the median dome-to-neck ratio was 1.8 (interquartile range, 1.6-1.9), the most common aneurysm locations were the anterior communicating artery (33%) and basilar artery tip (33%). After a median follow-up of 6.5 months, adequate aneurysm occlusion was achieved in 83%. There were 3 major ischemic complications (25%), leading to 2 permanent neurologic deficits (17%) and 1 transient neurologic deficit (8%). There was 1 fatal rupture of a treated aneurysm 1.6 months after the index treatment. Two patients were retreated (17%). Ischemic complications occurred in patients after a too-dense coil packing at the base of the aneurysm. No technical issues related to the device were encountered. In summary, an adequate aneurysm occlusion rate was achieved using the Trenza-assisted coiling technique for otherwise challenging mid-to-large-sized broad-neck aneurysms. Ischemic complications seemed to occur following overdense coiling at the base of the aneurysm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- From the Department of Neurosurgery (R.R.), Helsinki University Hospital and University of Helsinki, Helsinki, Finland rahul.raj@hus.fi.
- Department of Radiology (J.N.), Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
ORCID-Profile: Rahul Raj, Jussi Numminen
Förderung
- Helsinki University Hospital
Zitieren
APA
Raj, R., & Numminen, J. (2024). Initial Experiences with the Trenza Embolization Device for the Treatment of Wide-Neck Intracranial Aneurysms: A 12-Patient Case Series. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a8153
Vancouver
Raj R, Numminen J. Initial Experiences with the Trenza Embolization Device for the Treatment of Wide-Neck Intracranial Aneurysms: A 12-Patient Case Series. American Journal of Neuroradiology. 2024. doi:10.3174/ajnr.a8153
BibTeX
@article{Raj2024,
author = {Raj, Rahul and Numminen, Jussi},
title = {Initial Experiences with the Trenza Embolization Device for the Treatment of Wide-Neck Intracranial Aneurysms: A 12-Patient Case Series},
journal = {American Journal of Neuroradiology},
year = {2024},
doi = {10.3174/ajnr.a8153}
}