American Journal of Neuroradiology · 2024-04 · 45 (4) · 374-378
DOI: 10.3174/ajnr.a8119 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Neuroradiology, online erschienen am 18.01.2024. Verfasst von Vladimir Ivanovic und 6 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology, Section of Neuroradiology (V.I., J.F.H., R.B.), Medical College of Wisconsin, Milwaukee, Wisconsin Vladimir.ivanovi…. Hauptthemen laut MEDLINE: Radiology. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: Unlike in Europe and Japan, guidelines or recommendations from specialized radiological societies on workflow management and adaptive intervention to reduce error rates are currently lacking in the United States. This study of neuroradiologic reads at a large US academic medical center, which may hopefully contribute to this discussion, found a direct relationship between error rate and shift volume. MATERIALS AND METHODS: CT and MR imaging reports from our institution's Neuroradiology Quality Assurance database (years 2014-2020) were searched for attending physician errors. Data were collected on shift volume specific error rates per 1000 interpreted studies and RADPEER scores. Optimal cutoff points for 2, 3 and 4 groups of shift volumes were computed along with subgroups' error rates. RESULTS: A total of 643 errors were found, 91.7% of which were clinically significant (RADPEER 2b, 3b). The overall error rate (errors/1000 examinations) was 2.36. The best single shift volume cutoff point generated 2 groups: ≤ 26 studies (error rate 1.59) and > 26 studies (2.58; OR: 1.63, P < .001). The best 2 shift volume cutoff points generated 3 shift volume groups: ≤ 19 (1.34), 20-28 (1.88; OR: 1.4, P = .1) and ≥ 29 (2.6; OR: 1.94, P < .001). The best 3 shift volume cutoff points generated 4 groups: ≤ 24 (1.59), 25-66 (2.44; OR: 1.54, P < .001), 67-90 (3.03; OR: 1.91, P < .001), and ≥ 91 (2.07; OR: 1.30, P = .25). The group with shift volume ≥ 91 had a limited sample size. CONCLUSIONS: Lower shift volumes yielded significantly lower error rates. The lowest error rates were observed with shift volumes that were limited to 19-26 studies. Error rates at shift volumes between 67-90 studies were 226% higher, compared with the error rate at shift volumes of ≤ 19 studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- From the Department of Radiology, Section of Neuroradiology (V.I., J.F.H., R.B.), Medical College of Wisconsin, Milwaukee, Wisconsin Vladimir.ivanovic@yahoo.com.
- Department of Statistics (K.B.), Colorado State University, Fort Collins, Colorado.
- Department of Radiology, Section of Neuroradiology (Y.-M.C.), Beth Israel Deaconess Medical Center, Boston, Massachusetts.
- From the Department of Radiology, Section of Neuroradiology (V.I., J.F.H., R.B.), Medical College of Wisconsin, Milwaukee, Wisconsin.
- Department of Radiology, Section of Neuroradiology (L.H.-B.), University of California Davis Medical Center, Sacramento, California.
- Department of Public Health Sciences (L.Q.), School of Medicine, University of California Davis, Davis, California.
ORCID-Profile: Vladimir Ivanovic, Kenneth Broadhead, Yu-Ming Chang, Lotfi Hacein-Bey
Förderung
- NCI NIH HHS
Zitieren
APA
Ivanovic, V., Broadhead, K., Chang, Y. M., Hamer, J. F., Beck, R., Hacein-Bey, L., & Qi, L. (2024). Shift Volume Directly Impacts Neuroradiology Error Rate at a Large Academic Medical Center: The Case for Volume Limits. American Journal of Neuroradiology, 45(4), 374-378. https://doi.org/10.3174/ajnr.a8119
Vancouver
Ivanovic V, Broadhead K, Chang YM, Hamer JF, Beck R, Hacein-Bey L, et al. Shift Volume Directly Impacts Neuroradiology Error Rate at a Large Academic Medical Center: The Case for Volume Limits. American Journal of Neuroradiology. 2024;45(4):374-378. doi:10.3174/ajnr.a8119
BibTeX
@article{Ivanovic2024,
author = {Ivanovic, Vladimir and Broadhead, Kenneth and Chang, Yu-Ming and Hamer, John F and Beck, Ryan and Hacein-Bey, Lotfi and Qi, Lihong},
title = {Shift Volume Directly Impacts Neuroradiology Error Rate at a Large Academic Medical Center: The Case for Volume Limits},
journal = {American Journal of Neuroradiology},
year = {2024},
volume = {45},
number = {4},
pages = {374--378},
doi = {10.3174/ajnr.a8119}
}
EUVIMED