EUVIMEDEUVIMED entdecken
Open Access

Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI

Lela Okromelidze iD, Vishal Patel iD, Rahul B Singh, Alfonso S Lopez Chiriboga, Shengzhen Tao iD, Xiangzhi Zhou iD, Sina Straub iD, Erin M Westerhold iD, Vivek Gupta, Amit K Agarwal iD, John V Murray, Amit Desai iD und 3 weitere

American Journal of Neuroradiology · 2024-01 · 45 (1) · 76-81

DOI: 10.3174/ajnr.a8083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Neuroradiology, online erschienen am 28.12.2023. Verfasst von Lela Okromelidze und 14 weiteren Autor:innen. Beteiligte Einrichtung: From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonv…. Hauptthemen laut MEDLINE: Multiple Sclerosis. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: An early and accurate diagnosis of multiple sclerosis remains challenging in clinical neurology. Established diagnostic methods have less than desirable sensitivity and specificity. An accurate, noninvasive diagnostic test for MS could have a major impact on diagnostic criteria. We compared the frequency of detection of the central vein sign (CVS) in white matter lesions of MS and controls on 7T T2*-weighted and SWI to 3T SWI. Additionally, we assessed the diagnostic performance of 7T T2*, 7T SWI, and 3T SWI for MS. MATERIALS AND METHODS: A retrospective case-control study was performed of patients with MS having both 7T MRI and 3T MRI. A control group of patients without MS was selected. Diagnosis of MS was established by board-certified neurologists with fellowship training in autoimmune neurology in line with the 2017 McDonald criteria. Percentage of lesions with a CVS was blindly measured for each technique. Diagnostic performance was computed by sensitivity, specificity, and positive and negative likelihood ratios (LRs). RESULTS: Sixty-one patients with MS (903 lesions) and 39 controls (1088 lesions) were included. 7T T2* showed significantly more CVS (87%) than both 7T SWI (73%) and 3T SWI (31%) (all P 40% of lesions with CVS on 7T T2* and >15% on 7T SWI, both sequences had an accuracy = 100%, sensitivity = 100%, specificity = 100%, infinite positive LR, and zero negative LR. Using an optimal threshold of >12%, 3T SWI had an accuracy = 96.0%, sensitivity = 93.4%, specificity = 100%, infinite positive LR, and negative LR = 0.066. CONCLUSIONS: 7T MRI had 100% sensitivity and specificity for the diagnosis of MS and is superior to 3T. Future revisions to MS diagnostic criteria may consider recommendations for 7T MRI and inclusion of CVS as a biomarker.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multiple SclerosisHumansCase-Control StudiesRetrospective StudiesMagnetic Resonance ImagingVeinsBrain

Autor:innen und Institutionen

  • From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Neurology (A.S.L.C., I.V.M.C.), Mayo Clinic, Jacksonville, Florida.
  • From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida middlebrooks.erik@mayo.edu.

ORCID-Profile: Lela Okromelidze, Vishal Patel, Shengzhen Tao, Xiangzhi Zhou, Sina Straub, Erin M Westerhold, Amit K Agarwal, Amit Desai, Erik H Middlebrooks

Zitieren

APA

Okromelidze, L., Patel, V., Singh, R. B., Lopez Chiriboga, A. S., Tao, S., Zhou, X., Straub, S., Westerhold, E. M., Gupta, V., Agarwal, A. K., Murray, J. V., Desai, A., Sandhu, S. J. S., Marin Collazo, I. V., & Middlebrooks, E. H. (2024). Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI. American Journal of Neuroradiology, 45(1), 76-81. https://doi.org/10.3174/ajnr.a8083

Vancouver

Okromelidze L, Patel V, Singh RB, Lopez Chiriboga AS, Tao S, Zhou X, et al. Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI. American Journal of Neuroradiology. 2024;45(1):76-81. doi:10.3174/ajnr.a8083

BibTeX
@article{Okromelidze2024,
  author = {Okromelidze, Lela and Patel, Vishal and Singh, Rahul B and Lopez Chiriboga, Alfonso S and Tao, Shengzhen and Zhou, Xiangzhi and Straub, Sina and Westerhold, Erin M and Gupta, Vivek and Agarwal, Amit K and Murray, John V and Desai, Amit and Sandhu, S J S and Marin Collazo, I Vanessa and Middlebrooks, Erik H},
  title = {Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI},
  journal = {American Journal of Neuroradiology},
  year = {2024},
  volume = {45},
  number = {1},
  pages = {76--81},
  doi = {10.3174/ajnr.a8083}
}
Kostenlos starten →